FC-202P1K5T6131G9993 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Danfoss FC-202P1K5T6131G9993 is part of the VLT FC 202 AQUA Drives series and offers a power rating of 1.5 kW with an efficiency of 0.97. This three phase drive delivers 2.0 horsepower and supports a maximum ambient temperature of 50 degrees Celsius. It features a continuous input current of 2.7 A and is rated for IE2 energy efficiency class.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-202P1K5T6131G9993 is a variable-frequency drive produced by Danfoss within the VLT FC 202 AQUA Drives series. Designed for pump and fan duty in water and wastewater automation, the unit adjusts the speed of three-phase induction motors to match changing flow or pressure demands. This speed regulation can reduce energy consumption and mechanical wear by limiting unnecessary motor operation at full speed. The drive reaches an electrical efficiency of 0.97 and carries an IE2 energy-class rating, making it suitable for installations with minimum efficiency requirements.
The inverter delivers a continuous motor output of 1.5 kW, which corresponds to 2.0 HP. Its input and output sides each carry a nominal current of 2.7 A when the drive operates from a three-phase supply and feeds a motor rated for 551–600 V. Protective coordination permits a maximum pre-fuse value of 10 A, with a recommended gG-6 cartridge and an upper fuse limit of gG-25. These fuse values allow the upstream protective device to be selected according to the available circuit capacity. The electronics permit no more than two power-ups per minute, so the control system must avoid rapid power cycling. An internal trip level of 16 A disconnects the load when current rises substantially above the normal operating range.
During short overloads, the drive can supply 4.1 A to support temporary increases in motor demand. Its total power loss is limited to 65 W, which provides a basis for calculating ventilation and heat removal inside the enclosure. The drive can operate at ambient temperatures up to 50 °C without derating, allowing full output in many industrial control cabinets. Installations may use up to 150 m of shielded motor cable, supporting connections to pumps located far from the control panel. Field wiring accepts 4 mm² power conductors and 6 mm² disconnect links for connection to typical utility feeds. The shielded cable should be routed and terminated correctly to control electromagnetic interference between the drive, motor, and nearby automation equipment.