FC-202P1K5T6131G9993 Danfoss

Ask for Availability

Preparing your secure checkout page...

The Danfoss FC-202P1K5T6131G9993 is part of the VLT FC 202 AQUA Drives series and offers a power rating of 1.5 kW with an efficiency of 0.97. This three phase drive delivers 2.0 horsepower and supports a maximum ambient temperature of 50 degrees Celsius. It features a continuous input current of 2.7 A and is rated for IE2 energy efficiency class.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The FC-202P1K5T6131G9993 is a variable-frequency drive produced by Danfoss within the VLT FC 202 AQUA Drives series. Designed for pump and fan duty in water and wastewater automation, the unit adjusts the speed of three-phase induction motors to match changing flow or pressure demands. This speed regulation can reduce energy consumption and mechanical wear by limiting unnecessary motor operation at full speed. The drive reaches an electrical efficiency of 0.97 and carries an IE2 energy-class rating, making it suitable for installations with minimum efficiency requirements.

The inverter delivers a continuous motor output of 1.5 kW, which corresponds to 2.0 HP. Its input and output sides each carry a nominal current of 2.7 A when the drive operates from a three-phase supply and feeds a motor rated for 551–600 V. Protective coordination permits a maximum pre-fuse value of 10 A, with a recommended gG-6 cartridge and an upper fuse limit of gG-25. These fuse values allow the upstream protective device to be selected according to the available circuit capacity. The electronics permit no more than two power-ups per minute, so the control system must avoid rapid power cycling. An internal trip level of 16 A disconnects the load when current rises substantially above the normal operating range.

During short overloads, the drive can supply 4.1 A to support temporary increases in motor demand. Its total power loss is limited to 65 W, which provides a basis for calculating ventilation and heat removal inside the enclosure. The drive can operate at ambient temperatures up to 50 °C without derating, allowing full output in many industrial control cabinets. Installations may use up to 150 m of shielded motor cable, supporting connections to pumps located far from the control panel. Field wiring accepts 4 mm² power conductors and 6 mm² disconnect links for connection to typical utility feeds. The shielded cable should be routed and terminated correctly to control electromagnetic interference between the drive, motor, and nearby automation equipment.

Continuous Input Current
2.7 A
Continuous Output Current 551-600 V
2.7 A
Efficiency
0.97
Energy Efficiency Class
IE2
Estimated Power Loss
65 W
Horse Power
2.0 HP
Intermittent Output Current 551-600 V
4.1 A
Max Ambient Temperature
50 °C
Max Disconnect Cross-section
6 mm²
Max Input Power-ups
2 times/min
Max Power Cable Cross-section
4 mm²
Max Shielded Motor Cable
150 m
Maximum Fuse Size
gG-25
Maximum Pre-fuse
10 A
Maximum Trip Level
16 A
Power Phase
Three Phase Power
Power Rating
1.5 KW
Product Group
VLT AQUA Drive
Recommended Fuse Size
gG-6
Series Identifier
202

Frequently Asked Questions about FC-202P1K5T6131G9993:

Q: What is the continuous output current for the FC-202P1K5T6131G9993 drive?

A: The FC-202P1K5T6131G9993 from Danfoss can sustain a continuous output current of 2.7 A at 551-600 V.

Q: What is the maximum power cable cross-section permitted for this drive?

A: This model has a maximum power cable cross-section requirement of 4 mm².

Q: What is the rated power output of the FC-202P1K5T6131G9993?

A: The power rating of the FC-202P1K5T6131G9993 is specified at 1.5 kW.

Q: What fuse size is recommended for protecting the FC-202P1K5T6131G9993?

A: The recommended fuse size for this Danfoss drive is gG-6.

Q: What is the energy efficiency value of the FC-202P1K5T6131G9993?

A: This drive operates with a high efficiency of 0.97.


Internal Product Review

  • ‘‘The FC-202P1K5T6131G9993 is a Danfoss VLT FC 202 AQUA drive with a 1.5 kW rating for three-phase power applications. Efficiency at 0.97 and an IE2 energy efficiency class make the drive a strong fit for energy-conscious pumping systems. Reliable operation at ambient temperatures up to 50 °C is a standout specification.’’