FC-202P1K5T2134F6390 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
The Danfoss FC-202P1K5T2134F6390 is part of the VLT FC 202 AQUA Drives series and has a power rating of 1.5 kW with a continuous output current of 7.5 Amps. This drive operates on a mains voltage of 200 to 240 VAC, handles three phase power, and supports a maximum ambient temperature of 50 degrees Celsius. It features an efficiency of 0.96 and a full-load power loss of 82 Watts.
Internal Product Review
The FC-202P1K5T2134F6390 is a Danfoss VLT FC 202 AQUA Drive designed for 200 - 240 VAC three-phase power. A 1.5 kW rating paired with 0.96 efficiency gives this drive very attractive operating performance for water and pump applications. A maximum output frequency of 32 kHz stands out as a strong spec for smooth motor control.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-202P1K5T2134F6390 is a variable frequency drive produced by Danfoss for the VLT FC 202 AQUA Drives series. Classified under the VLT AQUA Drive product group, the unit converts a three-phase 200–240 VAC supply into a regulated output that allows industrial pump systems to match motor speed to process demand. With a power rating of 1.5 kW, equivalent to 2.0 HP, it is sized for small centrifugal pumps, blowers, and similar loads used in water treatment and irrigation systems.
During operation, the drive draws up to 6.8 A from the supply and delivers a continuous output of 7.5 A to the motor terminals. Its efficiency rating is 0.96, and operation at nominal load results in 82 W of full-load power loss that the heat sink must dissipate. The drive’s inverter stage can switch at frequencies up to 32 kHz, allowing low-noise motor operation, while the control board accepts analog speed references within a 200 Hz bandwidth for rapid setpoint changes. The drive provides 2.70 kVA of continuous apparent power and supports a maximum upstream fuse rating of 20 A. Power comes from a three-phase network and is routed through input terminals sized for 4 mm² line conductors or 6 mm² disconnect links. These terminal capacities accommodate the designated supply wiring while maintaining secure connections inside the enclosure.
For field installation, the drive supports shielded motor leads up to 150 m, allowing remote pump mounting without exceeding the inverter’s voltage-rise limits. It maintains full output when installed at elevations up to 1000 m above sea level, and its electronics can operate at ambient temperatures up to 50 °C. These operating limits allow the drive to function in control cabinets used in humid water-treatment facilities with minimal additional cooling. The unit delivers programmed speed profiles while built-in thermal monitoring reduces modulation if cooling airflow becomes blocked. This protective response helps prevent excessive semiconductor temperatures during extended operating cycles without interrupting the drive’s normal control functions unnecessarily.