FC-202P18KT2E66H2XGX3 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Danfoss FC-202P18KT2E66H2XGX3 is part of the VLT FC 202 AQUA Drives series and has a power rating of 18.5 kW or 25 HP. It operates on three phase 200 to 240 VAC power and features an IP66 / NEMA 4X protection level. The drive includes a graphical local control panel and is equipped with a mains disconnect, fuse, and RFI filter.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-202P18KT2E66H2XGX3 is a variable frequency drive manufactured by Danfoss for the VLT FC 202 AQUA Drives series. Intended for pump and fan duties in water treatment and irrigation plants, the unit converts fixed-frequency mains power into a controlled output that regulates motor speed in response to process demands. Using the drive instead of throttling valves or dampers can reduce energy consumption while maintaining stable flow, pressure, or liquid levels. Its variable-speed operation also allows connected equipment to respond more closely to changing demand rather than running continuously at full speed.
The drive has a continuous power rating of 18.5 kW, which corresponds to a mechanical motor output of 25 HP. The input section accepts a supply of 200–240 VAC and uses three-phase power, allowing connection to compatible low-voltage industrial feeders. The IP66/NEMA 4X enclosure protects the internal components against dust, powerful water jets, and corrosion, making the unit suitable for wall mounting in washdown pump rooms. The printed circuit boards are uncoated, so the installation location should prevent continuous condensation and excessive moisture from forming inside the enclosure. The FC 202 design supports the quadratic-torque operating profiles commonly required by centrifugal pumps and fans.
An integrated RFI filter helps suppress radio-frequency interference and limits conducted electrical noise on the supply network. The mains section includes a mains disconnect and fuse assembly, providing local isolation and overcurrent protection in a single installed arrangement. Local operation and parameter entry are handled through a graphical local control panel, which presents operating data through text displays and trend views. The drive has no brake chopper, so it cannot dissipate regenerative energy through an external dynamic braking resistor. During deceleration, the connected process must slow at a rate that keeps the returning energy within the drive’s operating limits. Pump and fan loads generally provide gradual deceleration because their mechanical inertia and fluid resistance reduce speed over time.