FC-202P18KT2131F1061 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
The Danfoss FC-202P18KT2131F1061 is a 25 HP drive from the VLT FC 202 AQUA Drives series designed for three phase 200 to 240 VAC power. This drive has a power rating of 18.5 kW, supports a max ambient temperature of 50°C, and can operate with relative humidity up to 95 percent. It features two analog inputs, two relay outputs, and supports shielded and unshielded motor cables up to 150 meters and 300 meters respectively.
Internal Product Review
The FC-202P18KT2131F1061 is a Danfoss VLT FC 202 AQUA Drive with a well-focused design for pump and water-process control. Power capability at 25 HP with 200 - 240 VAC input gives the drive strong application flexibility in lower-voltage three-phase installations. Control performance stands out through ±8 RPM speed accuracy and a system response time of ≤2 ms.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-202P18KT2131F1061 is a variable frequency drive manufactured by Danfoss for the VLT FC 202 AQUA Drives series. It provides adjustable-speed control for centrifugal pumps and fans in water and wastewater facilities. The drive allows motor output to follow real-time process demand, which can reduce energy use during periods of lower flow. Controlled acceleration and deceleration also reduce mechanical stress on pumps, motors, valves, and connected piping.
The drive supplies up to 18.5 kW, or 25 HP, of output power and operates from a 200–240 VAC mains supply using three-phase power. Speed regulation remains within ±8 RPM, and the internal control loop responds in ≤2 ms to support stable process pressure. Two analog inputs provide 10-bit resolution and a bandwidth of 200 Hz for accepting process signals from connected sensors and controllers. Associated 10 V and 24 V sources can deliver 25 mA and 200 mA, respectively, to external transducers. These inputs can receive feedback from pressure, flow, or level devices, allowing the drive to adjust motor speed as operating conditions change.
A 32 kHz digital output can source up to 40 mA for optically isolated inputs in supervisory control systems. Two form-C changeover relay outputs provide isolated contacts for pump permissive signals, operating status, or fault forwarding. The inverter tolerates ambient temperatures up to 50 °C and noncondensing relative humidity up to 95% without derating. Motor cables may extend up to 150 m when shielded to control electromagnetic interference, while unshielded motor cables may reach 300 m where the installation permits them. Line-side protection must use fuses rated no higher than 125 A to coordinate with the drive’s rectifier and DC link. The available analog, digital, and relay connections allow the drive to exchange process information with external automation equipment without requiring every signal to share the same interface type.