★★★★★
4.94 based on 222 reviews

🙶 Wake was very helpful in getting us a servo motor and drive for our tube mill line. This was the first tim... 🙷

FC-202P18KT2131F1061 Danfoss

Ask for Availability
No Hidden Fees Rush or Credit Card
No Tariffs On US Orders

Internal Product Review

The FC-202P18KT2131F1061 is a Danfoss VLT FC 202 AQUA Drive with a well-focused design for pump and water-process control. Power capability at 25 HP with 200 - 240 VAC input gives the drive strong application flexibility in lower-voltage three-phase installations. Control performance stands out through ±8 RPM speed accuracy and a system response time of ≤2 ms.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The FC-202P18KT2131F1061 is a variable frequency drive manufactured by Danfoss for the VLT FC 202 AQUA Drives series. It provides adjustable-speed control for centrifugal pumps and fans in water and wastewater facilities. The drive allows motor output to follow real-time process demand, which can reduce energy use during periods of lower flow. Controlled acceleration and deceleration also reduce mechanical stress on pumps, motors, valves, and connected piping.

The drive supplies up to 18.5 kW, or 25 HP, of output power and operates from a 200–240 VAC mains supply using three-phase power. Speed regulation remains within ±8 RPM, and the internal control loop responds in ≤2 ms to support stable process pressure. Two analog inputs provide 10-bit resolution and a bandwidth of 200 Hz for accepting process signals from connected sensors and controllers. Associated 10 V and 24 V sources can deliver 25 mA and 200 mA, respectively, to external transducers. These inputs can receive feedback from pressure, flow, or level devices, allowing the drive to adjust motor speed as operating conditions change.

A 32 kHz digital output can source up to 40 mA for optically isolated inputs in supervisory control systems. Two form-C changeover relay outputs provide isolated contacts for pump permissive signals, operating status, or fault forwarding. The inverter tolerates ambient temperatures up to 50 °C and noncondensing relative humidity up to 95% without derating. Motor cables may extend up to 150 m when shielded to control electromagnetic interference, while unshielded motor cables may reach 300 m where the installation permits them. Line-side protection must use fuses rated no higher than 125 A to coordinate with the drive’s rectifier and DC link. The available analog, digital, and relay connections allow the drive to exchange process information with external automation equipment without requiring every signal to share the same interface type.

10 V Output Load
25 mA
24 V Output Load
200 mA
Analog Input Bandwidth
200 Hz
Analog Input Resolution
10 bit
Analog Inputs
2
Digital Output Current
40 mA
Digital Output Frequency
32 kHz
Horse Power
25 HP
Mains Voltage
200 - 240 VAC
Max Ambient Temp
50 °C
Max Relative Humidity
95%
Maximum Pre-fuses
125 A
Power Phase
Three Phase Power
Power Rating
18.5 KW
Product Group
VLT AQUA Drive
Relay Outputs
2
Series Identifier
202
Shielded Motor Cable
150 m
Speed Accuracy
±8 RPM
System Response Time
≤2 ms
Unshielded Motor Cable
300 m

Frequently Asked Questions about FC-202P18KT2131F1061:

Q: What is the mains voltage range required for the FC-202P18KT2131F1061 drive?

A: The FC-202P18KT2131F1061 supports a mains voltage of 200 to 240 VAC for operation.

Q: What is the power rating of the Danfoss FC-202P18KT2131F1061?

A: This model features a power rating of 18.5 kW, making it suitable for demanding pumping or fan applications.

Q: How many analog inputs are provided and what is their resolution on the FC-202P18KT2131F1061?

A: Up to two analog inputs are available, each with a resolution of 10 bits and a bandwidth of 200 Hz.

Q: What is the maximum shielded motor cable length allowed with this Danfoss drive?

A: The FC-202P18KT2131F1061 allows the use of shielded motor cable lengths up to 150 meters.

Q: What is the speed accuracy specification of the FC-202P18KT2131F1061 drive?

A: This drive achieves speed accuracy within ±8 RPM for precise speed control applications.

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo