FC-202P15KT4E55H1XGX1OXSXXXXAXBXCXXXXDX Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
The Danfoss FC-202P15KT4E55H1XGX1OXSXXXXAXBXCXXXXDX is part of the VLT FC 202 AQUA Drives series and offers a power rating of 15 kW or 20 HP. This drive operates on three-phase power with a mains voltage of 380 to 480 VAC and has a protection level of IP55, type 12. It features a mains disconnect, a graphical local control panel, and an RFI filter rated class A1/B.
Internal Product Review
The FC-202P15KT4E55H1XGX1OXSXXXXAXBXCXXXXDX is a Danfoss VLT AQUA drive with a 15 kW rating. Three-phase 380 to 480 VAC input supports smooth integration into demanding pump and water-handling systems. A graphical local control panel and IP55 / Type 12 protection make this drive especially appealing for accessible operation and dependable enclosure performance.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-202P15KT4E55H1XGX1OXSXXXXAXBXCXXXXDX is a variable frequency drive produced by Danfoss for the VLT FC 202 AQUA Drives series. It regulates motor speed in pumping and water-treatment systems, allowing precise flow control and reduced energy consumption in applications that use centrifugal pumps and blowers. By varying the frequency and voltage supplied to the motor, the drive can adjust pump output as process demand changes instead of requiring the motor to operate continuously at full speed.
This model supplies up to 15 kW of continuous electrical output, which corresponds to a motor shaft rating of 20 HP. It accepts a utility supply of 380–480 VAC and operates with three-phase power, allowing direct connection to common industrial mains without phase conversion. The enclosure carries an IP55 / Type 12 rating, protecting internal components against dust, water jets, and incidental contact. This protection permits installation in suitable mechanical rooms without requiring a separate protective cabinet. The drive does not include an internal brake chopper, so an external braking arrangement is required when an application produces substantial regenerative energy. Cable glands use metric threads, which should be considered when selecting conduit fittings and cable-entry hardware. The printed circuit boards are uncoated, so the installation location should remain within the operating conditions established for the base design.
An integral RFI Class A1/B (C1) filter attenuates conducted electromagnetic emissions on the incoming mains lines. Local operation and parameter entry are performed through the graphical local control panel, which presents contextual text and operating information instead of relying solely on numeric codes. The interface provides direct access to operating status, motor settings, pump-control parameters, alarms, and diagnostic information. For service isolation, the power section incorporates a mains disconnect rated for the drive’s voltage and current range. This disconnect allows incoming power to be isolated at the unit before electrical service begins, although applicable lockout procedures must still be followed. A standard language pack is preloaded to provide multilingual menus for local operation and parameter entry.