FC-202P11KT6131Z9029 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
The Danfoss FC-202P11KT6131Z9029 is part of the VLT FC 202 AQUA Drives series and delivers a power rating of 11 kW with a horse power of 15 HP. This drive supports three phase power, operates at an AC line voltage of 525–600 V AC, and has an efficiency of 0.98. Its maximum output current is 19 A at 525-550 V and it features 4 digital inputs, with a maximum ambient temperature of 50°C.
Internal Product Review
The FC-202P11KT6131Z9029 is a Danfoss VLT FC 202 AQUA drive with an 11 kW power rating and 15 HP capacity. Support for 525–600 V AC and three-phase power makes integration straightforward in demanding water and process installations. Efficiency of 0.98 is a strong technical advantage for energy-conscious drive applications.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The FC-202P11KT6131Z9029 is an AC variable frequency drive produced by Danfoss within the VLT FC 202 AQUA Drives series. By varying output frequency and voltage, it provides closed-loop speed control for centrifugal pumps and fans. The drive is designed for water and wastewater treatment, distribution, and irrigation systems across industrial facilities. Its pump-oriented control functions help regulate flow and pressure as operating demand changes, reducing the need for mechanical throttling. The Series Identifier 202 aligns the drive’s input and output layout and mechanical format with other pump-oriented controllers in the series.
Within a plant electrical system, the drive accepts 525–600 V AC three-phase input power and converts it to a pulse-width-modulated output that follows the commanded speed. The power stage supports 11 kW of continuous shaft power, equivalent to 15 HP. When connected to a 525–550 V supply, the drive can deliver a continuous motor current of 19 A, while current on the incoming side remains below 17.2 A. Overall conversion efficiency reaches 0.98, and the drive generates 300 W of heat during full-load operation. Four standard digital inputs accept discrete operating commands, and the input count can be expanded to six when additional control functions are needed. A 0/4–20 mA analog output transmits real-time operating data to supervisory control equipment.
The drive sustains full electrical performance at ambient temperatures up to 50 °C and at installation elevations reaching 1000 m. Upstream protection should be provided by a 40 A fuse or circuit breaker sized for the converter’s rectifier section. Danfoss permits motor leads up to 150 m when shielded cable is used. If unshielded conductors are acceptable, the maximum motor cable length increases to 300 m before reflected-voltage effects must be considered. These cable limits help control electrical stress at the motor terminals, particularly in installations with long conductor runs. Suitable cabinet ventilation must also remove the stated heat loss so that the drive remains within its permitted operating temperature range.