VLT 6102 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
The Danfoss VLT 6102 is part of the VLT 6000 HVAC Drives series and has a power rating of 75 kW. It features an output voltage adjustable from 0 to 100% of the supply voltage and a rated motor frequency of 50 or 60 Hz. This drive provides a displacement power factor greater than 0.98 and supports a maximum screened motor cable length of 150 meters.
Internal Product Review
The VLT 6102 is a Danfoss HVAC drive rated at 75 kW with 50/60 Hz motor frequency compatibility. Starting torque of 110% for 1 minute and break-away torque of 160% for 0.5 second support confident motor pickup and steady fan or pump control. A displacement power factor above 0.98 makes the unit an efficient, well-balanced choice for HVAC installations.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The VLT 6102 is an HVAC variable frequency drive developed by Danfoss as a member of the VLT 6000 HVAC Drives series. As an AC motor controller, it adjusts fan and pump speed to match airflow or water flow demands, lowering energy use in building automation systems. By converting fixed AC line power into a modulated output, the unit supplies closed-loop speed regulation for induction motors installed in air-handling units and chiller circuits.
The drive delivers a continuous mechanical output of up to 75 kW, allowing it to run large centrifugal fans and multistage pumps. Its inverter section varies the motor terminal voltage from 0 to 100% of the supply voltage, providing smooth startup operation. The line input accepts frequencies from 48 to 62 Hz with a tolerance of ±1% and permits a supply-voltage imbalance of ±3.0% without tripping. At full load, the displacement power factor remains above 0.98, limiting reactive current. Programmable acceleration profiles range from 1 to 3600 seconds, while the control algorithm can deliver 100% acceleration torque and 110% overload torque during speed changes. To release a locked rotor, the drive can apply 160% breakaway torque for 0.5 seconds, and unlimited output switching supports bypass or duty-standby arrangements.
The power stage withstands a prospective fault current of 100,000 A when the correct fusing is used. Rated motor frequency remains 50/60 Hz, and the converter delivers 110% starting torque for 1 minute to overcome system inertia before settling to the normal load. The nominal input power factor is 0.90, complementing the higher displacement power factor. Installation flexibility is supported by a maximum unshielded motor lead length of 300 m, allowing motors to be installed in remote mechanical rooms without booster reactors. The maximum shielded motor lead length is 150 m. These cabling limits allow the drive to use long motor connections while preserving the shielding required in installations where electromagnetic interference must be controlled.