VLT 6062 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
The Danfoss VLT 6062 is part of the VLT 6000 HVAC Drives series and is designed for HVAC applications. It features a typical shaft output of 45 kW with a 60 horsepower rating and achieves 0.96 efficiency. The drive supports maximum relative humidity of 95% non-condensing and operates up to an altitude of 1000 meters.
Internal Product Review
The VLT 6062 is a Danfoss HVAC drive rated for 60 HP service. Efficiency of 0.96 and coated environment class 3C3 support clean, energy-conscious operation in demanding installations. Humidity tolerance up to 95% non-condensing makes this unit an excellent choice for dependable HVAC duty.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The VLT 6062 variable frequency drive is produced by Danfoss for the VLT 6000 HVAC Drives series. It is intended for building automation systems in which centrifugal fans, pumps, or compressors require adjustable motor speed to maintain flow, pressure, or temperature setpoints without mechanical throttling. By converting fixed-frequency three-phase mains power into a modulated output, the unit supplies the controlled torque required by an HVAC load. This approach reduces energy consumption during periods of lower demand while maintaining stable operation.
The drive delivers a mechanical output of 60 HP, providing continuous power for large motors used in air-handling and water-circulation systems. Its overall efficiency is 0.96, meaning that approximately four percent of the input energy is lost as heat during nominal operation. Installation sites may be located up to 1000 m above sea level before derating becomes necessary. The electronics tolerate ambient moisture levels up to 95% under noncondensing conditions. These operating limits allow the drive to power large air handlers or chilled-water pumps while keeping cabinet heat losses low and sustaining motor torque at typical building elevations.
Populated circuit boards are available with a 3C3 coating for chemically harsh rooms, while uncoated boards classified as 3C2 are suitable for clean environments. Full-performance operation begins at 0 °C. A reduced-performance mode permits operation at temperatures as low as -10 °C in unconditioned equipment rooms. Control and serial wiring terminals accept conductors up to 1.5 mm², providing a consistent maximum wire size for input, output, and fieldbus connections. Appropriate temperature control, moisture prevention, and circuit-board protection should be considered when the drive is installed in air-handling units, variable-primary pumping stations, or other HVAC machinery.