No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Danfoss VLT 6032 is an HVAC drive from the VLT 6000 HVAC Drives series with a shaft output of 22 kW and a horsepower rating of 30 HP. It provides an acceleration torque of 100% and features a break-away torque of 160% for 0.5 seconds, as well as a maximum operating humidity of 95% non-condensing. This drive is designed for operation at altitudes up to 1000 meters and can handle a short-circuit current of 100,000 amps.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The VLT 6032 is an HVAC variable frequency drive produced by Danfoss for the VLT 6000 HVAC Drives series. Intended for industrial automation tasks that demand energy-efficient airflow or liquid circulation, the unit converts fixed-frequency mains power into a regulated output that lets facility controllers adjust induction motor speed. By trimming motor torque to match load conditions, the drive supports reduced energy consumption and lower mechanical stress in commercial and process-plant HVAC systems.
At the output terminals, the drive can deliver 22 kW of mechanical power, which corresponds to a motor capacity of 30 HP. Torque handling supports demanding starts and quick load changes. The drive provides 110% for 1 minute of starting torque, supplies 160% for 0.5 seconds of breakaway torque for static loads, and maintains 100% acceleration torque during ramps. Normal overload torque remains at 110%, allowing short process surges without tripping. The DC bus wiring between the drive and external components is limited to 25 m. Shielded motor leads can run up to 150 m, while unshielded leads can run up to 300 m. Electrical performance includes a true power factor of 0.90 and a maximum line short-circuit withstand current of 100,000 A. The drive can operate at ambient temperatures as low as 0 °C and permits a mains voltage imbalance of ±1.5%.
The drive supports continuous operation at elevations up to 1000 m above sea level without derating. It remains stable in spaces where relative humidity reaches 95% RH, noncondensing. Supply-side efficiency is supported by a displacement power factor of greater than 0.98, which reduces reactive current. The available cable lengths allow the drive to be positioned away from the motor or incoming service when the required conductor type and routing practices are followed. Its short-circuit withstand capacity must be coordinated with suitable upstream protection and the available fault current at the installation point.