★★★★★
4.94 based on 219 reviews

🙶 We have never had a problem in the almost 20 years we have dealt with Wake. We would recommend them to any... 🙷

VLT 6016 Danfoss

In-Stock, Ships 3-5 Days
No Hidden Fees Rush or Credit Card
No Tariffs On US Orders

Internal Product Review

The VLT 6016 is a Danfoss HVAC drive rated for 11 kW output and suited for dependable building automation service. Strong drive behavior comes from 110% starting torque for 1 minute and 160% break-away torque for 0.5 s, which supports smooth fan and pump startup. Operation remains efficient with a displacement power factor above 0.98, making this unit a very capable choice for HVAC control.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The VLT 6016 is an AC frequency converter manufactured by Danfoss within the VLT 6000 HVAC Drives series. Designed for ventilation and pumping duties in building automation, the unit receives three-phase mains power and delivers a variable-frequency output that allows induction motors to accelerate smoothly, maintain constant pressure, and adapt to changing load profiles. By permitting speed control rather than throttling, it reduces electrical consumption and mechanical wear in commercial and industrial climate systems.

Its torque profile supports heavy fan wheels at startup. The drive can develop 110% starting torque for 1 minute during prolonged acceleration and provide 160% breakaway torque for 0.5 seconds to free stuck impellers. Under continuous load, the inverter supplies a typical shaft output of 11 kW, matching common 15 HP motors in rooftop air handlers. A true power factor of 0.90 indicates how effectively the input power is used, while an input phase-balance tolerance of ±1.5% keeps the control section within voltage limits on imperfect utility feeds. The output stage supports unlimited switching events per minute, allowing the controller to perform high-resolution modulation without accelerating wear on its transistors.

For electrical rooms with limited space, a minimum rear clearance of 200 mm is required to maintain airflow. The electronics operate at temperatures from 0 °C through 40 °C without derating. The assembly maintains operation at elevations up to 1000 m and tolerates 95% non-condensing humidity, enabling installation in humid mechanical penthouses. A displacement power factor of >0.98 minimizes reactive demand on the utility grid, supporting compliance with power-quality guidelines. Protection against upstream faults is provided for mains supplies with prospective currents as high as 100,000 A.

Break-away Torque
160% For 0.5 s
Displacement Power Factor
>0.98
Max Altitude
1000 m
Max Ambient Temperature
40°C
Max Operating Humidity
95% Non-Condensing
Max Short-circuit Current
100000 A
Max Supply Voltage Imbalance
±1.5%
Min Clearance
200 mm
Min Operating Temperature
0°C
Output Switching
Unlimited
Product Type
HVAC Drives
Starting Torque
110% For 1 Min
True Power Factor
0.90
Typical Shaft Output
11 kW

Frequently Asked Questions about VLT 6016:

Q: What is the typical shaft output power of the VLT 6016 drive?

A: The VLT 6016 provides a typical shaft output of 11 kW.

Q: How much break-away torque can the VLT 6016 HVAC drive achieve?

A: This model can deliver up to 160% break-away torque for 0.5 seconds.

Q: What is the maximum ambient temperature the VLT 6016 can operate in?

A: The VLT 6016 can operate at ambient temperatures up to 40°C.

Q: What is the maximum operating altitude for the VLT 6016 drive?

A: The VLT 6016 supports operation at altitudes up to 1000 meters.

Q: What is the maximum short-circuit current rating of the VLT 6016?

A: This drive has a maximum short-circuit current rating of 100,000 A.

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo