4.94 based on 219 reviews

🙶 Wake Ind. did a great job with very fast service getting us a motor driver to repair our critical robot sy... 🙷

VLT 6005 Danfoss

In-Stock, Ships 3-5 Days

Preparing your secure checkout page...

The Danfoss VLT 6005 is part of the VLT 6000 HVAC Drives series and is designed to deliver a typical shaft output of 3.0 kW or 4 HP. The drive features a starting torque of 110 percent, a speed control range of 1 to 100, and maintains a true power factor of 0.90. It supports a rated motor frequency of 50 or 60 Hz and can operate at altitudes up to 1000 meters with a maximum ambient temperature of 45°C.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The VLT 6005 is a variable-speed HVAC drive manufactured by Danfoss within the VLT 6000 HVAC Drives series. Designed for fan and pump duty, the unit modulates induction-motor speed and torque to match real-time thermal loads in air-handling and chiller circuits. By converting fixed utility frequency into a controlled output, the drive helps building automation systems reduce energy demand while maintaining stable airflow.

The output frequency can be trimmed in increments of ±0.003 Hz, and a wide speed range of 1:100 permits slow operation during night setback as well as full-speed purge cycles. Dynamic commands are processed within 3 ms, so pressure or flow loops remain stable when dampers or valves shift. Electrical efficiency is supported by a displacement-corrected true power factor of 0.90. The drive can overcome static load friction because breakaway torque reaches 160%, and it supplies 110% overload torque for one minute to handle transient peaks. It supports motors designed for either 50 Hz or 60 Hz networks and accepts a phase voltage imbalance of ±2.0% without tripping.

The unit maintains full output at elevations up to 1000 m and at ambient temperatures up to 45 °C inside IP20 enclosures. It can operate in air with relative humidity as high as 95% without condensation. The control sections can withstand a prospective short-circuit current of 100,000 A, supporting installation on high-capacity utility supplies. A vibration tolerance of 0.7 g RMS supports operation in locations subject to moderate mechanical movement. For medium-frame motors, the drive can deliver continuous shaft power of 3.0 kW. Its control response accommodates changing fan, pump, and compressor loads without disrupting regulated pressure or flow. The IP20 enclosure protects against accidental contact with internal electrical components while allowing the airflow needed for thermal management.

Break-away Torque
160%
Frequency Resolution
±0.003 Hz
Max Altitude
1000 m
Max Ambient Temp (ip20)
45°C
Max Humidity (op)
95%
Max Short-circuit Current
100,000 A
Max Supply Imbalance
±2.0%
Overload Torque
110%
Product Type
HVAC Drives
Rated Motor Frequency
50/60 Hz
Speed Control Range
1:100
Starting Torque
110%
System Response Time
3 ms
True Power Factor
0.90
Typical Output (hp)
4 HP
Typical Shaft Output
3.0 kW
Vibration Level
0.7 g RMS

Frequently Asked Questions about VLT 6005:

Q: What is the typical shaft output power of the VLT 6005 drive?

A: The VLT 6005 provides a typical shaft output of 3.0 kW for driving HVAC systems efficiently.

Q: What break-away torque capability does the VLT 6005 offer?

A: This model can deliver a break-away torque of up to 160%, allowing for strong initial motor starts.

Q: What is the frequency resolution of the VLT 6005 drive?

A: The VLT 6005 has a frequency resolution of ±0.003 Hz, ensuring precise speed control for HVAC applications.

Q: What is the maximum ambient temperature rating for the VLT 6005?

A: This drive allows operation at ambient temperatures up to 45°C in IP20 installations.

Q: What is the speed control range for the VLT 6005 HVAC drive?

A: The VLT 6005 achieves a 1:100 speed control range, supporting flexible motor speed adjustments for varied operational needs.


Internal Product Review

  • ‘‘The Danfoss VLT 6005 is an HVAC drive tuned for dependable building-system control, with 3.0 kW typical shaft output and 50/60 Hz rated motor frequency. A 1:100 speed control range and 3 ms system response time support stable modulation and clean adjustment under varying fan and pump loads. High control quality stands out through ±0.003 Hz frequency resolution, a key advantage for precise HVAC drive performance.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo