The 178B2007 is a robust VLT drive with a frequency range of 0 - 1000 Hz and a system response time under 3 milliseconds. Manufactured by Danfoss as part of the VLT 6000 HVAC Drives series, it boasts a maximum shielded motor cable length of 500 feet. The device offers precision speed control in both open and closed loops.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The Danfoss 178B2007 is a high-tech drive of the VLT 6000 HVAC Drives family. It was designed specifically for heating, ventilation, and air conditioning systems that need accurate and flexible motor control. This drive can work with a wide range of frequencies, from 0 to 1000 Hz, which makes it very flexible for managing the speed of three-phase standard AC motors. It can link motor cables that are up to 1000 feet long for unshielded cables and up to 500 feet long for shielded cables. This makes it good for installations where extensive cable lengths are needed without losing performance. The drive makes sure that the speed is always correct and that the performance is always dependable. For motor speeds below 1500 rpm, the speed is accurate to within ±7.5 rpm.

This level of accuracy is very important in places where airflow or pressure has to stay the same, such HVAC systems in commercial or industrial buildings. Standard features include integrated motor overload safety and factory settings that keep an eye on the motor's temperature conditions. By default, Parameter 117, Motor Thermal Protection, is set to ETR trip 1. This means that protection starts at 1.0 times the rated motor current and frequency, which helps keep the motor from overheating and makes it last longer.

The VLT 6000 HVAC series stands out because it can handle a broad range of power levels, from 1.1 kW to 500 kW. It also comes with a choice of enclosure options, such as IP20 and IP54 classifications, that may be installed next to each other to save space. There is also an IP00 enclosure for bigger power capacities, such 90 kW (and 30 kW for 200 V systems), which gives you even more options for unique installations.

Frequency Range
0 - 1000 Hz
Max Cross-section Control Cables
1.5 mm² (16 AWG)
Max Cross-section Serial Communication
1.5 mm² (16 AWG)
Max Dc-bus Cable Length (shielded)
25 m
Max Load sharing Cable Length (screened)
25 m
Max Motor Cable Length (shielded)
500 feet
Max Motor Cable Length (unshielded)
1000 feet
Resolution On Output Frequency
±0.003 Hz
Speed Accuracy (above 1500 Rpm, Closed Loop)
max. error 0.1% of actual speed
Speed Accuracy (above 1500 Rpm, Open Loop)
max. error 0.5% of actual speed
Speed Accuracy (below 1500 Rpm, Closed Loop)
max. error ±1.5 rpm
Speed Accuracy (below 1500 Rpm, Open Loop)
max. error ±7.5 rpm
Speed Control Range (closed Loop)
1:1000 of synchro speed
Speed Control Range (open Loop)
1:100 of synchro speed
System Response Time
< 3 ms

Frequently Asked Questions about 178B2007:

Q: What is the maximum shielded motor cable length for the 178B2007?

A: The maximum shielded motor cable length is 500 feet, ensuring reliable performance and signal integrity.

Q: How long can the unshielded motor cable be?

A: The maximum unshielded motor cable length is 1000 feet, which allows for flexible installation in various setups.

Q: What is the maximum shielded DC-bus cable length?

A: The maximum shielded DC-bus cable length is 25 meters, supporting safe and effective DC power transmission.

Q: How long can the screened loadsharing cable be for this model?

A: The maximum screened loadsharing cable length is 25 meters, suitable for synchronized operation across multiple devices.

Q: What is the maximum cross-section for control cables?

A: The maximum allowable cross-section for control cables is 1.5 mm² (16 AWG), ensuring compatibility with standard control wiring.


Internal Product Review

  • ‘‘The Danfoss 178B2007 is one of the VLT 6000 HVAC Drives family. It can handle frequencies from 0 to 1000 Hz. For unshielded cables, it can handle a maximum motor cable length of 1000 feet. For shielded cables, it can handle a maximum length of 500 feet. The drive makes sure that the speed is accurate within ±7.5 rpm below 1500 rpm.’’