VLT 5006 Danfoss

In-Stock, Ships 1-2 Days

Preparing your secure checkout page...

The Danfoss VLT 5006 is part of the VLT 5000 Frequency Converters series and delivers a starting torque of 160 percent for 1 minute, with a peak starting torque of 180 percent for 0.5 seconds. It features a closed-loop speed range of 1 to 1000 of synchronous speed and maintains a true power factor of 0.90. The system has a response time of 3 milliseconds and operates reliably up to 95 percent non-condensing humidity.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The VLT 5006 is a frequency converter produced by Danfoss within the VLT 5000 Frequency Converters series. Designed for plant-level automation, the drive converts constant three-phase mains power into a programmed AC output that allows controllers to match motor speed and torque to process demand, reducing mechanical stress and energy consumption in conveyors, pumps, and general machinery. For fault containment, the power stage withstands a symmetrical short-circuit current of 100,000 A when properly fused, providing coordination with high-capacity industrial feeders.

The acceleration torque reaches 100% of the motor rating, allowing rapid ramp-up without stalling. When a load is applied at standstill, the converter can deliver a starting torque of 160% for 1 minute, with a short-burst capability of 180% for 0.5 seconds to overcome static friction. Closed-loop regulation has a speed range of 1:1000 relative to synchronous speed, allowing precise low-speed positioning under feedback control. The microprocessor and current regulators react within a 3 ms system response window, while the inverter updates its output with a frequency resolution of ±0.003 Hz to provide smooth transitions during speed and torque changes.

The converter can operate at up to 95% non-condensing humidity, and stored units can tolerate 93% relative humidity without damage. The incoming line may deviate by ±2.0% from nominal, and the drive compensates for that imbalance while holding motor current within ±2.0% of its commanded value. Internal control algorithms maintain displacement and distortion performance that produces a power factor of 0.90 at rated load, reducing reactive demand on the supply network. The available current regulation helps the connected motor maintain stable operation when line conditions or mechanical loads fluctuate within the permitted ranges.

Acceleration Torque
100%
Closed-loop Speed Range
1:1000 of synchro. speed
Max Operating Humidity
95% non-condensing
Max Short-circuit Rating
100,000 A
Max Storage Humidity
93%
Max Supply Imbalance
±2.0% of rated supply voltage
Motor Current Accuracy
±2.0% of rated output current
Output Frequency Resolution
±0.003 Hz
Overload Torque
160%
Peak Starting Torque
180% for 0.5 sec
Product Type
VLT 5000
Starting Torque
160% for 1 min
System Response Time
3 msec
True Power Factor
0.90

Frequently Asked Questions about VLT 5006:

Q: What is the peak starting torque capability of the VLT 5006 frequency converter?

A: The VLT 5006 delivers a peak starting torque of 180% for 0.5 seconds.

Q: What is the output frequency resolution for the VLT 5006?

A: This model offers an output frequency resolution of ±0.003 Hz, enabling precise motor speed control.

Q: What is the maximum operating humidity allowed for the VLT 5006?

A: The VLT 5006 can operate in environments with up to 95% non-condensing humidity.

Q: What is the system response time of the Danfoss VLT 5006?

A: The system has a response time of 3 milliseconds, ensuring quick adjustments to control changes.

Q: What closed-loop speed range does the VLT 5006 frequency converter support?

A: The VLT 5006 supports a closed-loop speed range of 1:1000 of synchronous speed.


Internal Product Review

  • ‘‘The VLT 5006 is a Danfoss VLT 5000 frequency converter suited for precise motor control in demanding industrial drive applications. A closed-loop speed range to 1:1000 of synchronous speed and output frequency resolution of ±0.003 Hz support impressively stable regulation. Starting torque of 160% for 1 minute highlights strong low-speed performance.’’