VLT 5004 Danfoss

In-Stock, Ships 1-2 Days

Preparing your secure checkout page...

The Danfoss VLT 5004 is a frequency converter in the VLT 5000 Frequency Converters series. It offers a starting torque of 160 percent for 1 minute and a peak starting torque of 180 percent for 0.5 seconds. The drive has a true power factor of 0.90, a system response time of 3 milliseconds, and supports a speed control range of 1 to 1000 in closed-loop mode.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The VLT 5004 frequency converter is produced by Danfoss within the VLT 5000 Frequency Converters series. It is an AC drive that modulates the output frequency supplied to an induction motor so plant controllers can regulate shaft speed, torque, and process throughput without mechanical throttling. Designed for industrial automation, the unit connects directly to standard three-phase mains and provides control terminals for closed-loop or open-loop operation. This configuration makes it suitable for conveyors, pumps, and fan systems that require precise electrical speed regulation.

Speed regulation accuracy is supported by a frequency resolution of ±0.003 Hz, allowing the drive to issue fine increments that help keep motor slip minimal. In closed-loop mode, the controller spans a ratio of 1:1000, so feedback devices can maintain slow creep speeds as reliably as full production rates. When fast acceleration is required, the converter can deliver 180% of rated torque for 0.5 seconds, while a starting reserve of 160% for one minute supports heavy loads until steady-state operation is reached. Command changes propagate quickly because the internal vector processor has a response time of 3 ms. Electrical efficiency is supported by a true displacement power factor of 0.90. The input section tolerates a supply imbalance of up to ±2.0%, allowing operation with uneven mains phases in plant switchboards.

Power terminals accept conductors with cross-sectional areas of up to 4 mm², supporting connections for typical medium-frame motors. Shielded motor cables may run up to 150 m without exceeding the applicable switching limits. Brake, serial communication, and load-sharing circuits require shorter cable runs. The unit has a maximum short-circuit rating of 100,000 A, permitting installation on feeders protected by suitable high-capacity fuses. Shielded brake cables can extend up to 20 m, while load-sharing connections may reach 25 m. These permitted cable lengths provide flexibility when the converter and related equipment are installed in distributed control panels.

Frequency Resolution
±0.003 Hz
Max Brake Cable Length (screened)
20 m
Max Control Cable Cross-section
1.5 mm2
Max Loadsharing Cable Length (screened)
25 m
Max Motor Cable Cross-section
4 mm2
Max Motor Cable Length (screened)
150 m
Max Power Cable Cross-section
4 mm2
Max Serial Cable Cross-section
1.5 mm2
Max Short-circuit Rating
100000 A
Peak Starting Torque
180% for 0.5 sec
Product Type
VLT 5000
Speed Control Range (closed-loop)
1:1000
Speed Control Range (open-loop)
1:100
Starting Torque
160% for 1 min
Supply Imbalance Tolerance
±2.0% of rated supply voltage
System Response Time
3 msec
True Power Factor
0.90

Frequently Asked Questions about VLT 5004:

Q: What is the closed-loop speed control range of the VLT 5004?

A: The VLT 5004 offers a closed-loop speed control range of 1:1000 for precise motor speed management.

Q: What is the system response time of the VLT 5004 frequency converter?

A: The system response time for the VLT 5004 is 3 milliseconds.

Q: What peak starting torque can the VLT 5004 provide?

A: This model delivers a peak starting torque of 180% for 0.5 seconds.

Q: How long can the screened motor cable be when used with the VLT 5004?

A: The maximum screened motor cable length supported by the VLT 5004 is 150 meters.

Q: What supply imbalance tolerance does the VLT 5004 accept?

A: The VLT 5004 can tolerate a maximum supply voltage imbalance of ±2.0% of the rated supply voltage.


Internal Product Review

  • ‘‘The VLT 5004 is a Danfoss frequency converter with ±0.003 Hz frequency resolution and a 3 msec system response time. Closed-loop speed control to 1:1000 and 160% starting torque for 1 min give the drive strong low-speed regulation and dependable startup behavior. A true power factor of 0.90 makes the unit an efficient and well-balanced choice for demanding drive applications.’’