195N1111 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
MPN: VLT2880PT4B20STR3DBF00A00C0
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Danfoss 195N1111 is a low voltage drive from the VLT 2800 series with a power rating of 1.1 kW and a horse power of 1.5 HP. It features a NEMA 1 enclosure and a nominal output current of 24 Amps. The drive has an efficiency of 97 percent and supports a maximum motor cable size of 16 mm² (AWG 6).
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The 195N1111 is a low-voltage AC drive manufactured by Danfoss for the VLT 2800 Low Voltage Drives series. It converts constant three-phase mains power into variable-frequency output, allowing industrial control systems to adjust motor speed according to process demand. This electronic regulation reduces the need for mechanical throttling in material-handling, pumping, and HVAC equipment that requires consistent torque and moderate power. Its compact format supports installation in control cabinets for machinery that benefits from adjustable motor speed.
Operating efficiency is rated at 97%, so only a small portion of the input energy is lost as heat. The nominal motor phase current is 24 A, which serves as the continuous value used when sizing contactors and cabling. For short acceleration periods, the inverter can supply 38.4 A for 60 seconds before its protective limits engage. The power section has a maximum output of 1.1 kW (1.5 HP), making it suitable for common IEC-frame motors used in compact machinery. Power loss at full load is 412 W, and the generated heat is dissipated through the drive enclosure. The NEMA 1 enclosure is intended for protected indoor locations that are free from excessive moisture and contamination. An EN 55011-1B RFI filter is integrated to reduce conducted electrical interference. DeviceNet and Profibus DP fieldbus ports are not included, so control and communication rely on hardwired terminals.
Upstream protection should use a 50 A fuse to clear electrical faults safely. The circuitry can withstand a prospective short-circuit current of 100,000 A, supporting connection to high-capacity industrial feeders when suitable protective equipment is installed. A true power factor of 0.90 keeps the line current close to its active component and reduces unnecessary reactive current. The motor terminals accept conductors with cross-sectional areas up to 16 mm², equivalent to AWG 6, providing adequate capacity for the supported load. The drive does not include an integral brake, so external dynamic braking equipment is required when an application demands rapid deceleration. The unit weighs 18.5 kg, which helps limit the mechanical load placed on the cabinet mounting surface.