195N1059 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
MPN: VLT2822PT4B20STR1DBF30A00C0
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Danfoss 195N1059 is a low voltage drive from the VLT 2800 series, featuring a power rating of 0.55 kW and a maximum output current of 8.3 Amps. It has a device efficiency of 96 percent, comes with an IP20 enclosure, and provides five digital inputs and one relay output for control. This drive also supports DeviceNet fieldbus and has a power factor of 0.90.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The 195N1059 is a variable frequency AC drive manufactured by Danfoss for the VLT 2800 Low Voltage Drives series. Installed between the mains supply and a three-phase induction motor, it modulates output frequency to control shaft speed, allowing tighter process control and reduced mechanical wear. The device is intended for light-duty automation such as small conveyors, fans, and pumps. It connects to supervisory systems through the built-in DeviceNet interface for parameter downloads and real-time diagnostics.
Its power stage is rated at 0.55 kW, a level suited to fractional-horsepower machines that require regulated speed control. During continuous operation, the input line draws 4.7 A and supplies the inverter section, which delivers a nominal motor phase current of 5.2 A. Conversion efficiency reaches 96%, so only 4% of the electrical energy becomes heat under the stated operating conditions. The drive has a true power factor of 0.90, which helps keep reactive power demand low. Five digital inputs accept start, stop, and preset speed commands, while a single relay output can transmit operating status to auxiliary equipment. The integrated EN 55011-1A filter attenuates radio-frequency interference and reduces conducted emissions on the supply lines.
The drive is housed in an IP20 open-type enclosure, so it must be mounted inside a switchboard that provides suitable protection against accidental contact. During overload events, it can supply up to 8.3 A for 60 seconds without tripping. The recommended upstream fuse rating is 20 A, and the short-circuit withstand capacity is 100,000 A. Thermal planning should account for 110 W of power loss at full load, and the three-phase terminals accommodate RFI-filtered cabling routed through the cabinet. The unit weighs 3.7 kg, which makes it easier to position and secure during panel assembly.