The Danfoss 195N1043 is part of the VLT 2800 Low Voltage Drives series and features a 2.0 horsepower rating with a power output of 1.5 kW. It operates on a 380-480V three-phase mains voltage and provides IP20 protection, along with a built-in display. This drive includes a bookstyle enclosure and comes with an EN 55011 Class A1 RFI filter.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The 195N1043 is an adjustable-speed AC drive produced by Danfoss for the VLT 2800 Low Voltage Drives series. Acting as the interface between plant power and a squirrel-cage motor, the unit produces a variable-frequency output that allows conveyors, mixers, and other continuous-process machines to match production demand without mechanical throttling. Its compact dimensions and DIN-rail-friendly mounting support installation inside modern automation enclosures where available panel space is limited. The drive regulates motor speed electronically, allowing connected equipment to operate at the speed required by the process rather than continuously running at full output.
This model delivers a continuous mechanical output of 1.5 kW, corresponding to a nominal shaft rating of 2.0 HP. The input section accepts 380–480 V, ±10%, 50/60 Hz from a three-phase supply, allowing connection to common industrial power systems within that voltage range. Conducted emissions are limited by an integrated EN 55011 Class A1 radio-frequency interference filter, making the unit suitable for commercial and light-industrial switchboards that meet the applicable installation requirements. An IP20 protection rating helps prevent accidental finger contact with live parts when the drive is installed correctly. Additional enclosure protection is required where the equipment may be exposed to dust, moisture, dripping liquids, or direct water contact.
The mechanical layout uses a book-style format, so the heat sink fins and terminals align with adjacent modules while conserving cabinet width. Parameters can be entered and reviewed through the built-in display (SLCP) without requiring a separate keypad for routine setup and operation. The drive uses the Standard configuration and does not include an optional application card. Because the circuit boards are supplied without a protective coating, the unit should be installed in a clean, dry location that is free from corrosive vapors and excessive airborne contamination. Suitable cabinet ventilation should allow heat to move away from the heat sink while maintaining the required clearances around the housing. Power, motor, and control wiring should be routed according to the applicable installation instructions to limit electrical interference and maintain dependable operation.