195N0073 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
MPN: VLT2840PT2B20STR0DBF00A00C0
The Danfoss 195N0073 is a 1.0 HP low voltage drive in the VLT 2800 Low Voltage Drives series, featuring an efficiency rating of 95 percent and a power rating of 0.75 kW. It has a maximum output current of 25.6 amps, supports a motor cable size of 4 mm² or AWG 10, and comes in an IP20 enclosure. This drive weighs 6.0 kg and offers a true power factor of 0.90.
Internal Product Review
The 195N0073 is a Danfoss VLT 2800 low voltage drive rated at 0.75 kW and 1.0 HP. A 95% efficiency level and 0.90 true power factor support clean, economical motor control in demanding applications. IP20 enclosure protection and a 100,000 A short-circuit rating make the unit an excellent low-voltage drive option.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The 195N0073 is a low-voltage AC drive from Danfoss that belongs to the VLT 2800 Low Voltage Drives series. It modulates three-phase mains power to regulate induction motor speed in conveyors, pumps, and fan systems, allowing closed-loop torque control without mechanical throttling. Its mass is 6.0 kg, so the drive can be mounted directly on standard DIN rails or backplates without additional bracing.
An operating efficiency of 95% limits wasted energy to 5 percent, which keeps internal heating low and simplifies cabinet ventilation. Under nominal load, the converter draws a rated input current of 14.7 A and supplies a rated output current of 16 A; these values support cable sizing and breaker selection for continuous service. A true power factor of 0.90 keeps reactive demand modest on the supply network. For overloads or acceleration events, the input current can reach 23.5 A, while the inverter section can momentarily deliver 25.6 A. These current levels help the drive start high-inertia machinery without nuisance trips. When the unit operates at full capacity, resistive and switching losses amount to 231 W, and this heat must be removed through panel airflow.
The power stage is rated at 0.75 kW and is protected by an enclosure classified as IP20, which prevents finger contact with hazardous internal components but does not provide protection against liquids. Supply circuits upstream must be fused at 25 A according to IEC or UL guidelines, and the internal design withstands fault currents up to 100,000 A when coordinated with suitable circuit breakers. Both motor and mains conductors connect to spring terminals that accept 4 mm² (AWG 10) cable, providing the same copper cross-section on the input and output sides. The dedicated ground connection accepts the same conductor size, helping maintain consistent impedance and minimize common-mode electrical noise on the motor lead.