134H2362
Wake Industrial LLC is not an authorized distributor of this product.
MPN: VLT2803PS2B20SBR1DBF12A00C1
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
-
In-Stock, Ships 1-2 Days
The 134H2362 drive features a rated motor power of 0.37 kW (0.5 HP), an input voltage of 3 x 200-240 V AC, an enclosure rating of IP20, and a compact design with dimensions of 150 x 75 x 143 mm. Part of the VLT 2800 Low Voltage Drives series by Danfoss, it operates at an input frequency of 50/60 Hz.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The Danfoss 134H2362 Frequency Converter is built for reliable motor control. It delivers precise shaft output while maintaining stable efficiency and performance. The unit is compact, lightweight and ensures safe operation under industrial power conditions. It is designed to optimize power conversion and supports continuous demanding workloads.
The 134H2362 frequency converter provides an output current of 2.2 A with a maximum of 3.5 A for 60 seconds. It delivers an output power rating of 0.9 kVA at 230 V. The typical shaft output of the model is 0.37 kW that is equivalent to 0.5 HP. For motor connections, it supports a maximum cable cross section of 4 mm² / AWG 10. The device requires an input current of 5.9 A for single phase 220 – 240 V supply and 2.9 A for three phase 200 – 240 V input. The peak input currents for 60 seconds reach 9.4 A in single phase and 4.6 A in three phase operation. The converter integrates cable cross section limits of 4 mm² / AWG 10 on the power side as well. The efficiency of the converter is maintained at 95 % with a power loss of 24 W at 100 % load. The total unit weight is 2.0 kg and it comes with enclosure type IP20. The supply frequency of this model is 50/60 Hz with tolerance of ± 3 Hz and the voltage imbalance tolerance is ± 2 % of the rated supply.
The 134H2362 frequency converter operates with a nominal true power factor of 0.90 at rated load and displacement power factor close to unity, above 0.98. It allows up to two supply input connections per minute for L1, L2 and L3. The short circuit withstand rating reaches 100,000 A that ensures high operational safety in fault conditions.
Frequently Asked Questions about 134H2362:
Q: How does the Danfoss 134H2362 ensure consistent efficiency during continuous industrial workloads?
A: The model sustains 95% efficiency with only 24 W power loss at full load. This performance allows stable shaft output of 0.37 kW under demanding operating cycles.
Q: What current handling capability does the 134H2362 frequency converter provide for different supply modes?
A: It requires 5.9 A for single phase input and 2.9 A for three phase input. Peak inrush values reach 9.4 A and 4.6 A for 60 seconds.
Q: How does the Danfoss 134H2362 address installation needs for safe motor connections?
A: It supports a maximum motor cable cross section of 4 mm² / AWG 10. The same cable size applies to the power side, ensuring reliable wiring integrity.
Q: What protections enhance operational safety in the 134H2362 frequency converter during fault conditions?
A: The converter withstands 100,000 A short circuit currents at rated input voltage. This rating secures equipment durability and provides high tolerance against internal or external electrical faults.
Q: How does the 134H2362 maintain reliable input stability under real-world supply fluctuations?
A: It accepts a supply frequency tolerance of ±3 Hz and voltage imbalance tolerance of ±2%. This range ensures dependable performance in environments with moderate grid variations.