195H3401

    In-Stock, Ships 1-2 Days

Preparing your secure checkout page...

The Danfoss 195H3401 is part of the VLT 2000 Frequency Converters series and operates as an AC drive with a power output of 0.75 kW. It features an IP20 enclosure, can handle input voltages of 380-460V AC, and supports a max output frequency of 500 Hz. The drive includes brake control and complies with EMC standards EN55011, Group 1, Class A.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

Danfoss designed 195H3401 variant with display feature allows local parameter viewing and on-unit status checks during commissioning and fault diagnosis. Dynamic brake control allows controlled stopping and mechanical holding for vertical loads or fast deceleration tasks. Its maximum ambient temperature is 40°C (Full Load) which defines the upper environmental limit for continuous rated operation and guides cabinet ventilation requirements.

The availability of EMC compliance is EN55011, Group 1, Class A with RFI filter which limits conducted and radiated emissions for industrial locations. The motor’s cable length (std) of 40 m supports typical machine layouts while maintaining EMC performance without special screening. Further, its line frequency is 50/60 Hz and this matches common supply standards and enables global application compatibility. This frequency inverter provides variable AC output for speed control across loaded profiles. With an output power of 0.75 kW, it indicates rated mechanical power capability for matching small motors. Output power is 1 HP and presents nominal imperial power equivalence for system documents. The continuous output current of 2.4 A maintains conductor sizing and protection device selection for sustained operation.

The module 195H3401 displays input voltage as 380-460 V AC, three-phase which combines with industrial mains and sets insulation and clearance requirements for wiring. The maximum output frequency is 500 Hz to run high frequency operation for specialized speed ranges. Enclosure safety of IP20 requires installation inside a cabinet for protection against contact and solids. Built-in thermal drive protection is electronic which provides motor thermistor emulation and helps prevent winding overheating under prolonged loading. Side-by-side mounting requires no side clearance, thus enables compact panel layouts and increases usable cabinet density.

Continuous Output Current
2.4 A
Display
With Display
Drive Type
Frequency Inverter (AC Drive)
Dynamic Brake
With Brake Control
Emc Compliance
EN55011, Group 1, Class A (with RFI filter)
Enclosure Rating
IP20
Input Voltage
380-460 V AC (Three-Phase)
Line Frequency
50/60 Hz
Max Ambient Temp.
40°C (Full Load)
Max Output Frequency
500 Hz
Motor Cable Length (std)
40 m (130 ft), up to 300 m (with coil)
Output Power (hp)
1 HP
Output Power (kw)
0.75 kW
Product Series
VLT 2000 Series

Frequently Asked Questions about 195H3401:

Q: What does the display on part 195H3401 provide and how does it affect commissioning?

A: The controller display presents local parameter entry and status values which shortens setup time and provides immediate diagnostic feedback for technicians.

Q: How does the dynamic brake option on part 195H3401 influence stopping performance?

A: The 195H3401 dynamic brake with brake control enables controlled deceleration and mechanical holding which allows safe stopping of inertia heavy loads.

Q: Why is the maximum ambient temperature specified for part 195H3401 important for installation planning?

A: Specifying 40°C (full load) for the 195H3401 variant sets the thermal limit for continuous operation. This directs ventilation design, cabinet placement, and duty scheduling to avoid overheating during rated output.

Q: How does EMC compliance apply to Danfoss’s 195H3401 in industrial settings?

A: Meeting EN55011 Group 1 Class A with RFI filter requires adherence to industrial EMC limits which influences device placement. This also ensures the 195H3401 will not exceed acceptable conducted or radiated emission levels within typical factory environments.

Q: What does the standard motor cable length for 195H3401 unit mean for machine layout?

A: This standard motor cable length of 40 m supports typical equipment layouts while preserving EMC performance, thus reducing the need for screened cables in many installations and simplifies cable routing.


Internal Product Review

  • ‘‘195H3401 from Danfoss is an ideal module of industrialists as it gives optimal results by pairing an onboard display with a frequency inverter architecture to support precise motor control. Including brake control and side-by-side mounting capability help manage vertical loads and conserve cabinet space as well.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo