The NXP00135-B2H1SSS-0000BED600+BM2U+FNPO2V191+APSG065+DNOT+GNUL by Danfoss, part of the VACON NXP Air Cooled Drives series, features motor shaft power up to 3 kW at 500 V. It has an operating frequency of 0 to 320 Hz, a nominal input current of 5.6 A, and dimensions of 128 × 292 × 190 mm.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
NXP00135-B2H1SSS-0000BED600+BM2U+FNPO2V191+APSG065+DNOT+GNUL is a NXP series air-cooled drive from Danfoss. A detailed product label is attached to the unit to aid identification. It lists the product type code, input rating, output specifications, and other relevant information including the serial number. This information on this label must be checked at delivery. NXP drives can include a control panel that functions as the interface between the drive and its operator. The control panel on NXP drive is removable. Each VACON NXP drive features a 9-key keypad which operators can use to control the drive, configure values, and monitor the drive. A fan is installed on NXP drives to force heated air away from the unit. Free space must be provided if multiple drives are installed close to each other. NXP00135-B2H1SSS-0000BED600+BM2U+FNPO2V191+APSG065+DNOT+GNUL is a drive with an input rating of 380 to 500 Volts AC.
The permitted input voltage tolerance range is -10 to 10%. The range of allowable AC mains frequencies is from 45 to 66 Hertz. The permitted frequency of connection to the AC mains is up to once per minute. Danfoss permits maximum network imbalance of ±3% of nominal input. Supported AC mains types include IT, TT, and TN. The peak short-circuit current threshold is 100 kiloamps. Rated output current of the drive unit is 13 Amps. NXP00135-B2H1SSS-0000BED600+BM2U+FNPO2V191+APSG065+DNOT+GNUL is a drive without a local control panel. Its housing complies with IP21 protection rating. An internal brake chopper is installed on the unit. Ideally, the ambient temperature must not go above 40 ⁰C. The standard range of output drive frequencies is 0 to 320 Hertz. If required, operators can order NXP drives with special software that allows output frequencies up to 7200 Hertz.
Frequently Asked Questions about NXP00135-B2H1SSS-0000BED600+BM2U+FNPO2V191+APSG065+DNOT+GNUL:
Q: Is a brake chopper installed on the drive?
A: An internal brake chopper is installed on the drive.
Q: Is a local control panel available on the drive?
A: A local control panel is not available on the drive.
Q: Which cooling method does the motor use?
A: The drive is equipped with a fan for forced-air cooling.
Q: What is the mounting orientation?
A: The mounting orientation is vertical.
Q: Which control algorithms are supported?
A: Supported control algorithms include sensorless vector and vector control.