NXL00095-C2H1SSS-0000 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Danfoss NXL00095-C2H1SSS-0000 belongs to the VACON NXP Air Cooled Drives series and features an internal brake chopper. This drive offers a nominal input current of 9 A, with high overload current at 7.6 A and low overload current at 9 A. Its compact design measures 292 mm in height, 128 mm in width, and 190 mm in depth, with a weight of 5 kilograms.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The NXL00095-C2H1SSS-0000 is an air-cooled variable frequency drive from Danfoss and belongs to the VACON NXL Frequency Converters series. The unit converts fixed-frequency three-phase mains power into a modulated output, allowing automation controllers to regulate induction motor speed and torque. It is intended for conveyors, pumps, and material-handling axes where adjustable motor output can replace mechanical throttling or fixed-speed operation. Its compact format supports installation in standard control cabinets, while the internal forced-air cooling system removes heat from the power electronics.
An integrated brake chopper controls regenerative energy during deceleration and can direct that energy to a compatible external braking resistor. The steel housing has an enclosure rating of IP21, providing protection against finger contact and vertically falling water drops. The drive meets C2 conducted-emission limits, making its filtering suitable for industrial power networks when installation requirements are followed. The housing measures 292 mm high, 128 mm wide, and 190 mm deep, allowing multiple units to be arranged efficiently within a cabinet. The nominal input current is 9 A, while the high-overload operating current is 7.6 A for a one-minute duty period. During that high-overload duty, the current can reach a 50 percent overload ceiling of 11.4 A. A separate low-overload operating limit supports loads that require lighter transient torque.
DC bus supervision activates at 911 VDC on the high side and 333 VDC on the low side, helping protect the power stage from abnormal supply conditions. When supplied from a 380 V line, the inverter delivers 4 kW at 10 percent overload, while a 500 V supply increases the continuous output to 5.5 kW under the same duty profile. An aluminum heat sink and forced-air channel dissipate operating heat while keeping the unit’s overall mass at 5 kg. Power and motor cables can be routed beneath the 128 mm-wide base, and the cabinet must provide adequate clearance around the cooling fins to maintain unrestricted airflow. The drive’s narrow housing helps preserve adjacent panel space for protective devices, contactors, and cable management components.