MPN: MCD50595CT5G4X00CV2
The Danfoss 175G5541 is a soft starter from the MCD Soft Starters series, supporting three phase power and featuring an insulation voltage of 690 V AC. It has a protection rating of IP00 and requires an external bypass contactor. The soft starter provides a relay output rating of 10 Amps at 250 V AC and weighs 45 kg.
Internal Product Review
The 175G5541 is a Danfoss MCD soft starter built for three-phase power applications, with a specification set well suited to demanding motor control duties. IP00 construction and a 65 kA short-circuit rating support dependable panel integration in industrial drive assemblies. A 690 V AC insulation voltage is a particularly strong electrical highlight.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The 175G5541 soft starter is produced by Danfoss and is supplied within the MCD Soft Starters series. As a solid-state starter, it governs the initial voltage applied to three-phase induction motors, controlling the current rise so conveyors, pumps, or fans reach operating speed without disruptive torque. By performing this ramp function, the device provides an important interface between mains power and motion equipment in automated process plants.
The unit operates from three-phase power and provides a 24 V DC control output for field electronics; loop impedances up to 600 Ω can be connected without exceeding the analog driver limit. The mains section carries an insulation rating of 690 V AC and tolerates impulse overvoltages up to 4 kV. Silicon-controlled rectifiers are rated for a thermal let-through of 1,200,000 A²s, while the assembly maintains a fault withstand rating of 65 kA when coordinated with upstream protection. The IP00 construction requires the starter to be installed inside a ventilated panel. An external bypass contactor is required after full motor voltage is reached. A thermistor trip activates if the motor sensor resistance rises above 3.6 kΩ, adding overtemperature protection to the start sequence.
The auxiliary 24 V DC rail can supply up to 200 mA for indicator lamps, relays, or PLC inputs. The thermal design supports non-bypassed peak currents of 893 A when the starter is wired in delta and 595 A for an in-line installation, allowing selection according to the motor topology. Two programmable relay contacts are fitted, and each contact can switch 10 A at 250 V AC for run, fault, or alarm signaling. The starter belongs to the VLT Soft Starter MCD product group and weighs 45 kg. Its weight must be considered when selecting the panel structure and handling equipment.