175G5540 Danfoss

In-Stock, Ships 1-2 Days
Current Response Time 3 min 34 sec
No Hidden Fees Rush or Credit Card
No Tariffs On US Orders

Internal Product Review

The 175G5540 is a Danfoss MCD soft starter designed for three-phase power systems with a rated insulation voltage of 690 V AC. In-line performance is strong, with a 428 A continuous rating and a 430 A bypassed rating for steady motor starting duty. High short-circuit capability up to 65 kA makes the 175G5540 a very capable choice for demanding industrial motor control.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The 175G5540 is a soft starter manufactured by Danfoss for the MCD Soft Starters series. Installed between the utility supply and a three-phase motor, it modulates SCR firing angles so the motor accelerates under controlled voltage, limiting inrush current and mechanical stress on couplings, pulleys, and driven equipment. Within automated plants, the device provides a compact alternative to across-the-line contactors when smoother torque transmission and reduced electrical loading are required.

When wired in the conventional in-line configuration, the controller can deliver a continuous motor current of 428 A and can handle short-term bypassed operation at up to 430 A after the motor reaches full speed. The minimum full-load current setting is 86 A, allowing correct adjustment for smaller machines connected to the same frame size. Its rated insulation withstand voltage is 690 V AC, matching common 600 V class distribution systems, and the internal control circuitry endures transient overvoltages up to 4 kV. For branch-circuit protection, a maximum Class J fuse of 450 A may be fitted. The starter operates on three-phase power and carries an open-chassis IP00 protection level, so it must be mounted inside a suitable enclosure with adequate airflow.

Inside-delta wiring increases current capability; in this mode, the unit supports continuous conduction at 643 A and bypassed current of up to 645 A. Its short-circuit current rating reaches 65 kA for three cycles when protected by the required fusing, while its standard fault-current endurance is 30 kA. A relay output rated at 10 A and 250 V AC can signal operating status to a PLC, and a 24 V DC auxiliary source supplies up to 200 mA for external sensors. The SCR thermal limit has an I²t value of 320,000 A²s. The assembly is 689 mm high, weighs 35 kg, and uses bolted bus connections for integration with low-voltage motor control centers.

24 Vdc Output Load
200 mA
Height
689 mm
Impulse Withstand
4 kV
In-line Bypassed Rating
430 A
In-line Continuous Rating
428 A
Inside Delta Bypassed Rating
645 A
Inside Delta Continuous Rating
643 A
Max Fuse Rating
450 A (Class J)
Min In-line Flc Setting
86 A
Phase Power
Three Phase Power
Product Group
VLT Soft Starter MCD
Protection
IP00
Rated Insulation Voltage
690 V AC
Relay Output Rating
10 A @ 250 V AC
Scr I2t
320000 A²s
Standard Fault Current
30 kA
Three-cycle Sccr
65 kA
Weight
35 kg

Frequently Asked Questions about 175G5540:

Q: What type of power supply does the 175G5540 soft starter use?

A: The Danfoss 175G5540 soft starter supports three phase power for industrial motor applications.

Q: What is the in-line continuous current rating for the 175G5540?

A: The 175G5540 soft starter has an in-line continuous rating of 428 A, making it suitable for high current loads.

Q: What level of enclosure protection does the 175G5540 feature?

A: This model has a protection level of IP00, meaning it should be installed within a secured enclosure.

Q: What is the maximum fuse rating recommended for the 175G5540 soft starter?

A: The maximum fuse rating for the 175G5540 is 450 A using a Class J fuse.

Q: What is the standard fault current capacity of the Danfoss 175G5540?

A: The standard fault current capacity for this unit is 30 kA, supporting robust short-circuit protection.