The 175G5537 is a Danfoss VLT Soft Starter MCD for three-phase power systems with a rated insulation voltage of 690 V AC. AC-53a in-line duty at 245 A and IEC prospective current of 85 kA give the soft starter strong capability for demanding motor starting applications. IP00 protection suits enclosed installations, and the 10 A at 250 V AC relay output is a valuable control feature.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The 175G5537 is a solid-state soft starter manufactured by Danfoss in the MCD Soft Starters series. It is designed for three-phase induction motors and ramps the voltage during startup and shutdown to reduce inrush current, mechanical shock, and electrical stress on connected equipment. Within an automated plant, the unit sits between the mains supply and the motor, providing controlled acceleration and deceleration for pumps, compressors, and conveyors. This operating method can reduce abrupt pressure changes in pumping systems and limit drivetrain stress in material-handling equipment.

The power section is rated for a maximum line voltage of 690 V AC, and its silicon devices can withstand impulse transients up to 4 kV. When wired in the standard in-line topology, the starter handles a motor full-load current of 245 A. In an inside-delta connection, the permissible current rises to 368 A. During normal operation, the motor’s nameplate current must remain below 255 A to maintain acceptable thermal conditions. The control relays provide 10 A switching at 250 V AC, while an analog output can drive 0–10 V instrumentation loads with an impedance of at least 600 Ω. The unit also provides a 24 V DC auxiliary supply at 200 mA and routes bypass conductors through terminals T1B, T2B, and T3B. Its IP00 protection rating requires installation inside an enclosure that provides suitable protection and adequate airflow.

The standard short-circuit rating at 600 V is 18 kA, while the UL three-cycle short-circuit rating reaches 65 kA. These ratings assist with the selection of compatible upstream breakers and fuses. A prospective IEC fault current of 85 kA establishes the available fault-current level for protection planning. The SCR has an I²t rating of 320,000 A²s, and the maximum fuse rating is 350 A, setting the applicable energy let-through limits during a fault. The assembly has a mass of 23.9 kg, which must be considered when selecting panel supports and mounting hardware. Relay outputs provide switching connections for external control circuits, and the analog interface supports connection to compatible monitoring equipment.

24 V Dc Output
200 mA
Analog Output Load
600 Ω
Bypass Terminals
T1B, T2B, T3B
Iec Prospective Current
85 kA
Impulse Withstand Voltage
4 kV
In-line Ac-53a 3-30:50-6
245 A
Inside Delta Ac-53a 3-30:50-6
368 A
Max Fuse Rating
350 A
Max In-line Flc
255 A
Phase Power
Three Phase Power
Product Group
VLT Soft Starter MCD
Protection
IP00
Rated Insulation Voltage
690 V AC
Relay Output Rating
10 A @ 250 V AC
Scr I2t
320000 A2s
Standard Fault Sccr (600 V)
18 kA
Ul 3-cycle Sccr (600 V)
65 kA
Weight
23.9 kg

Frequently Asked Questions about 175G5537:

Q: What is the maximum 24 V DC output current available from the 175G5537?

A: The Danfoss 175G5537 soft starter provides a 24 V DC output current up to 200 mA.

Q: What type of power phase is used by the 175G5537 soft starter?

A: This model supports three-phase power operation for industrial motor control.

Q: What is the maximum fuse rating for the Danfoss 175G5537?

A: The maximum fuse rating for the 175G5537 soft starter is 350 A.

Q: What level of protection does the 175G5537 offer according to the IP rating?

A: The 175G5537 has an IP00 protection rating, indicating no ingress protection is provided.

Q: Which bypass terminals are included on the Danfoss 175G5537?

A: This soft starter features bypass terminals labeled T1B, T2B, and T3B.