175G5537
Wake Industrial LLC is not an authorized distributor of this product.
MPN: MCD50245CT5G3X00CV2
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
-
Available
The 175G5537 soft starter boasts a rated voltage of 200-525 VAC, a rated current of 245 amps, and a start current of 4.5 times the full load current. Part of the MCD Soft Starters series by Danfoss, it features an IP00 enclosure rating and adaptive acceleration control for optimized performance.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
Engineered by the Danfoss brand, the 175G5537 variant records starts per hour as 10 which limits mechanical and thermal cycling. This further defines acceptable start frequency for duty scheduling. Its control voltage options list 110 VAC and 220 VAC, allowing connection to typical industrial control supplies and simplify control transformer selection. Rated current is 245A and can set the continuous current threshold and guides cable sizing and breaker selection for sustained operation.
Adaptive Acceleration Control is included to provide closed loop start profiling and adjusts acceleration to limit torque and current excursions. Frame size of “G3” determines chassis envelope and mounting clearances for panel layout. On-load duty cycle is 70 percent and limits the permitted run time under load and informs cooling and duty planning. The module’s start current is 4.5 x FLC which defines the peak starting current multiple for thermal and protection calculations. Further, its rated voltage spans 200 to 525 VAC to support broad supply ranges and reduces need for transformers. Current rating bypasses is 255 A which specifies the bypassed continuous current capacity for in-line operation. The enclosure rating is IP00 which indicates no enclosure ingress protection and requires external guarding or enclosure.
This soft starter 175G5537 specifies start time as 30 s and sets the maximum programmable ramp interval and constrains thermal stress during long starts. Rated mains frequency of 50/60 Hertz which matches common industrial supplies and affects protection and monitoring set points. Gross weight for this variant is 27 kg which defines shipping and handling requirements for installation planning. Alos, its net weight is 24 kg. This model code MCD50245CT5G3X00CV2 identifies the factory configuration for ordering and documentation retrieval.
Frequently Asked Questions about 175G5537:
Q: How is the control voltage defined for the 175G5537?
A: The control voltage options are 110 VAC and 220 VAC. These voltages determine compatible control circuits and transformer needs.
Q: What is the starts per hour specification for the model 175G5537?
A: Its starts per hour value is 10 which defines the allowed number of start cycles in one hour and controls thermal accumulation in the starter and motor.
Q: What rated current does the 175G5537 specify?
A: The module represents rated current of 245 A. This specifies the continuous current capacity that the starter will carry and it guides breaker and cable selection.
Q: What frame size is assigned to the 175G5537 unit?
A: The frame size of G3 represents physical dimensions and mounting interfaces for panel integration. Cabinet layout must account for the G3 envelope.
Q: Which adaptive control feature is present in the 175G5537?
A: The unit includes Adaptive Acceleration Control to measure motor conditions and adjusts acceleration to reduce torque and current peaks.