Internal Product Review

The 175G5534 is a Danfoss VLT Soft Starter MCD engineered for three-phase power and rated for 690 V AC insulation. Short-circuit capability of 65 kA and SCR I²t of 320000 A²s support confident protection during demanding motor starts. Strong 170 A max FLC in-line capacity makes the unit a very capable soft starter for industrial duty.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The 175G5534 soft starter is built by Danfoss for the MCD Soft Starters series. Used in three-phase motor feeders, it ramps current and voltage to limit mechanical stress and utility supply disturbances when large induction motors start. Belonging to the VLT Soft Starter MCD product group, the unit is applied wherever across-the-line switching would exceed the available short-circuit capacity or overload couplings. It supports three-phase power connections and accepts a 24 V DC logic supply, allowing PLCs to manage start, stop, and diagnostic functions.

The control input draws 24 V DC at 8 mA, so panel designers can energize the starter directly from common auxiliary supplies without additional relays. An analog output with ±5% accuracy can operate meters or control devices and may be loaded up to 600 Ω; this is the minimum impedance required to keep the transmitter within its linear range. The internal electronics resist impulse voltages up to 4 kV between the power and control circuits, supporting installation in switchboards exposed to lightning or capacitor-bank switching. For motor sizing, the starter handles a maximum full-load current of 170 A when wired inline, while the AC-53b 3-30:570 profile permits 141 A of cyclic duty. Power is transferred through copper lugs that must be tightened to 38 Nm. The enclosure has an IP00 rating, so the starter requires installation inside a dedicated cabinet that provides adequate protection and cooling airflow.

When wired in an inside-delta configuration, the starter carries 212 A under the same AC-53b duty class, expanding the usable motor size without increasing the line conductor rating. The internal SCR stack withstands an I²t value of 320,000 A²s and supports a prospective system fault current of 65 kA, allowing upstream fuses to clear faults without damaging the semiconductor. A 24 V DC auxiliary output supplies up to 200 mA for sensor power. An onboard relay rated at 10 A at 250 V AC provides run status to external interlocks. Functional insulation is certified for 690 V AC, while the thermistor input trips the starter when motor resistance rises above 3.6 kΩ to prevent overheating.

24 Vdc Output Max Load
200 mA
Analog Output Accuracy
±5%
Analog Output Max Load
600 Ω
Impulse Withstand Voltage
4 kV
In-line Ac-53b 3-30:570
141 A
Input Rating
24 V DC, 8 mA
Inside Delta Ac-53b 3-30:570
212 A
Max Flc (in-line)
170 A
Phase Power
Three Phase Power
Power Terminal Torque
38 Nm
Product Group
VLT Soft Starter MCD
Protection Rating
IP00
Rated Insulation Voltage
690 V AC
Relay Output Rating
10 A @ 250 V AC
Scr I²t
320000 A²s
Short-circuit Capability
65 kA
Thermistor Trip
>3.6 kΩ

Frequently Asked Questions about 175G5534:

Q: What is the maximum analog output load supported by the 175G5534 soft starter?

A: The Danfoss 175G5534 offers a maximum analog output load of 600 Ω, enabling compatibility with a wide range of control systems.

Q: What is the maximum FLC supported in-line by the 175G5534?

A: This model supports a maximum FLC (Full Load Current) of 170 A when configured for in-line operation.

Q: What type of power phase does the 175G5534 operate on?

A: The 175G5534 is built for three phase power applications, providing reliable motor starting for industrial equipment.

Q: What is the rated insulation voltage for the 175G5534?

A: This soft starter features a rated insulation voltage of 690 V AC, supporting usage in high-voltage systems.

Q: What is the protection rating of the 175G5534 soft starter?

A: The Danfoss 175G5534 provides a protection rating of IP00, indicating it does not have protection against ingress of solid objects or liquids.