MPN: MCD202045T6CV1
The Danfoss 175G5248 is a soft starter from the MCD Soft Starters series, designed for three-phase power with a power rating of 45 kW and a mains voltage range of 200 to 575 VAC. It features an IP20 protection rating, a relay output rated at 6 A and 250 VAC, and supports a control supply voltage of 24 VAC/VDC.
Internal Product Review
The 175G5248 is a Danfoss MCD202 soft starter designed for three-phase power systems with a power rating of 45 kW and mains voltage support from 200 to 575 VAC. Its IP20 protection rating and EMC Class B compliance make it well-suited for controlled environments. The combination of high relay output rating and a 10 kA short-circuit rating ensures reliable protection and performance in demanding applications.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The 175G5248 is a soft starter produced by Danfoss within the MCD Soft Starters series. This device is installed between the mains supply and an induction motor to limit inrush current and mechanical stress during ramp-up and ramp-down. By managing voltage on three phases, it enables smoother acceleration, reduces torque peaks, and protects downstream equipment in pumping, conveying, and fan applications. Because voltage is applied in a controlled manner, connected couplings, belts, and pumps are subjected to less abrupt loading during start and stop.
The unit can handle motors up to 45 kW, so it fits medium-power industrial drives. Its main terminals accept line voltages from 200-575 VAC, allowing use on common 208 V, 400 V, and 480 V networks. The internal control board is energized by a separate 24 VAC/VDC source, which isolates logic circuits from mains disturbances. During startup, that control circuit draws an inrush of 2 A before settling to a lower steady current. EMC performance is graded as Class B, meaning the starter satisfies residential as well as light-industrial emission limits when properly installed. Additional parameters include a maximum control input of 300 VAC for external run commands, three-phase power, and a thermistor cutout threshold of 2.8 kΩ that permits direct connection to standard motor thermal sensors.
Protective features complement the ramp functions. The semiconductor stack withstands short-circuit events up to 10 kA when coordinated with the recommended fuses. A programmable relay contact rated at 6 A, 250 VAC can signal run status or trip conditions to supervisory systems. The housing carries an IP20 rating, so live parts are finger-safe when the starter is mounted inside a panel with adequate airflow. Phase-loss or imbalance is detected, and a fixed delay of 3 s prevents nuisance trips during brief supply dips. This arrangement helps the soft starter remain stable when the incoming supply is temporarily disturbed.