175G5218 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
MPN: MCD202090T4CV3
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Danfoss 175G5218 is a soft starter from the MCD Soft Starters series, designed for three phase power applications and featuring a power rating of 90 kW. It has a control supply voltage of 110 to 240 VAC or 440 VAC and supports a frame size of C-Frame. This model offers a heavy duty rating of 142 A and a normal duty rating of 170 A, with an IP00 protection rating.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The 175G5218 is a solid-state motor soft starter from Danfoss and belongs to the MCD Soft Starters series in the MCD 202 product group. It is intended for three-phase power installations where gradual motor acceleration lowers mechanical stress and limits line disturbances during startup. By controlling the voltage applied to induction motors, the device helps maintain predictable torque and reduces inrush peaks in industrial automation lines. This soft starter is useful where controlled acceleration helps reduce belt shock, pressure surges, or abrupt load changes at startup.
This model supports line supplies from 200-440 VAC and can deliver up to 90 kW of motor power in the compact C-Frame. The control circuit accepts 110/240 VAC or a single 440 VAC source, allowing it to match available auxiliary power. For high-load applications, the heavy-duty rating is 142 A: AC53b 4-20:580, and the assembly withstands prospective faults up to 10 kA when protected by the recommended fuses. The enclosure has an IP00 protection rating, so the unit must be installed inside a suitable cabinet. Three solid-state phases provide balanced soft starting and stopping for motors connected to a three-phase power network, and the built-in bypass contactor reduces heat after the ramp sequence finishes.
During normal-duty cycles, the unit handles 170 A: AC53b 4-6:594, making it suitable for pumps, fans, and conveyors with moderate starting torque. The initial gate-drive stage draws an inrush control current of 10 A, and steady operation of the electronics requires only 100 mA Max. A main SCR bypass contact rated at 6 A / 250 VAC and a relay output with the same rating provide status or run feedback to external logic. This arrangement also allows connected controls to receive simple operating signals without extra switching hardware. Phase-sequence monitoring, combined with the soft ramp profiles, helps protect motors against abnormal line conditions without adding mechanical contact wear.
Frequently Asked Questions about 175G5218:
Q: What power phase does the Danfoss 175G5218 support?
A: The 175G5218 soft starter is designed to operate with three phase power.
Q: What is the normal duty rating for the 175G5218 soft starter?
A: The 175G5218 offers a normal duty current rating of 170 A (AC53b 4-6:594).
Q: What is the maximum power rating of the 175G5218 soft starter?
A: The power rating for the Danfoss 175G5218 soft starter is 90 kW.
Q: What is the protection rating of the 175G5218?
A: This model has a protection rating of IP00, meaning it does not have integral enclosure protection.
Q: What control supply voltages does the Danfoss 175G5218 accept?
A: The control supply voltage for the 175G5218 can be either 110/240 VAC or 440 VAC.