136G7352 Danfoss
Wake Industrial LLC is not an authorized distributor of this product.
MPN: MCD60244BT5S2X00CV2
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Danfoss 136G7352 is a three phase soft starter from the MCD Soft Starters series, supporting a mains voltage of 200 to 525 V AC and a rated insulation voltage of 690 V AC. It features an internal bypass contactor, offers a rated current of 244 Amps, and has a control voltage range of 110-120/220-240 V AC. The protection rating is IP00 and it is rated for short-circuit currents up to 18 kA at 600 V AC.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The 136G7352 is a motor soft starter produced by Danfoss as part of the MCD Soft Starters series. Acting as an electronic stage between a three-phase mains supply and an AC induction motor, the unit controls the initial voltage gradient so belts, pumps, and fans accelerate smoothly, minimizing torque shock and extending mechanical service life in automated installations. Its integrated bypass contactor transfers running current away from the power semiconductors once full speed is reached, reducing heat and overall energy dissipation during steady-state operation.
The starter accepts line supplies from 200-525 V AC across three phases and is dimensioned for a continuous motor draw of 244 A. An internal bypass architecture, implemented through an internal bypass contactor, eliminates thyristor losses after ramp-up, which helps panels stay cooler. The logic circuitry is energized by a control input of 110-120/220-240 V AC, permitting installation on either standard plant voltage level without auxiliary transformers, and it draws 600 mA from that source. This control supply range allows the unit to fit panels that use either of the common AC control voltages. Transient overvoltages encountered on industrial feeders are tolerated up to 6 kV of impulse withstand, while the insulation system is rated at 690 V AC to separate power components from grounded metalwork.
For panel builders, physical protection is classified as IP00, so the device must be mounted inside an enclosure that provides the required touch-safe barriers. Its analog output can drive monitoring equipment up to 600 Ω, allowing proportional current or torque feedback to remote PLC inputs. Fault relays are sized for 10 A @ 250 V AC, and the power stage survives prospective faults up to 18 kA @ 600 V AC when backed by suitable upstream fuses, ensuring coordination with common MCCB ratings. The starter can also provide both analog status signaling and relay-based fault indication to external control hardware.
Frequently Asked Questions about 136G7352:
Q: What type of power phase does the Danfoss 136G7352 soft starter support?
A: The 136G7352 soft starter is designed for three-phase power applications.
Q: What control voltage options does the 136G7352 soft starter require?
A: This model operates with a control voltage range of 110-120 or 220-240 V AC.
Q: What is the protection rating for the Danfoss 136G7352 soft starter?
A: The protection rating for the 136G7352 is IP00, meaning it does not include enclosure protection.
Q: What is the rated current capacity of the 136G7352 soft starter?
A: The maximum rated current for the 136G7352 is 244 A.
Q: What type of bypass system is used in the Danfoss 136G7352?
A: An internal bypass contactor is featured in the 136G7352 soft starter.