The Danfoss 132H2269 is part of the MCD Soft Starters series and is rated for 200 HP motors with a mains voltage of 480 V AC. This enclosed heavy duty soft starter offers three phase power, features an internal bypass contactor, and operates with a rated current of 240 Amps. It uses a 120 VAC control voltage and is housed in a NEMA 3R enclosure.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The 132H2269 soft starter is produced by Danfoss within the MCD Soft Starters series. It is installed between the line supply and an induction motor to limit inrush current and reduce mechanical shock during startup, which helps protect couplings, belts, and other driven components. By controlling voltage during acceleration, it can also reduce voltage dip on the plant power system when large motors start under load. This makes starting more controlled on conveyors, pumps, fans, and similar motor-driven equipment. The unit uses an enclosed housing, so live parts are isolated from touch and the assembly is better suited for protected industrial mounting.
The starter supports motors rated up to 200 HP and operates from a 480 V AC line supply. Its power section is rated for 240 A of continuous line current, so upstream protection and conductors must be selected for that load. The control circuit uses 120 VAC from a separate source, allowing the logic section to remain independent of the main power path. Because it is built for three-phase power, the SCRs regulate each phase evenly during acceleration. The enclosure carries a NEMA 3R rating, which allows use in outdoor locations exposed to falling rain or sleet while still providing ventilation for heat dissipation.
A built-in internal bypass contactor transfers the motor off the thyristors after the ramp is complete, which reduces semiconductor heating during normal running. After the motor reaches speed, current flows through the bypass path instead of the SCR stack, helping the unit manage heat during long operating periods. That reduction in running losses can help keep internal temperatures more stable when the motor remains at full speed for extended periods. The cabinet uses an enclosed heavy-duty design with reinforced spacing and components intended for frequent starts in demanding conveyor or pump service. The power section remains enclosed during operation, which helps maintain touch protection inside the cabinet.
Frequently Asked Questions about 132H2269:
Q: What is the rated current of the Danfoss 132H2269 soft starter?
A: The 132H2269 soft starter has a rated current of 240 A, suited for large motors.
Q: What input mains voltage does the 132H2269 soft starter operate on?
A: This model supports a mains voltage of 480 V AC, allowing it to handle typical industrial power supplies.
Q: What is the control voltage required for the 132H2269?
A: The control voltage for this soft starter is 120 VAC.
Q: What type of bypass is included in the Danfoss 132H2269 soft starter?
A: The 132H2269 comes with an internal bypass contactor, reducing heat generation during operation.
Q: What is the enclosure rating and type for the 132H2269 soft starter?
A: This model features a NEMA 3R enclosed heavy duty enclosure suitable for outdoor use.