MPN: X4C50075C
The Danfoss VACONX4C50075C is part of the Low Voltage VACON X Drives series and features a three-phase input with a voltage rating of 575 Vac. This drive has an IP66 rating, a frame size of T1, and supports high overload power of 5 HP while delivering low overload power up to 7.5 HP. It measures 306 mm in height, 221 mm in width, 166 mm in depth, and weighs 6.35 kg.
Internal Product Review
The VACONX4C50075C is a low-voltage drive engineered for 3-phase 575 Vac systems. An IP66 enclosure and ±15% input tolerance support dependable operation in demanding installations. The 7.5 HP low-overload rating makes the VACONX4C50075C a strong choice for sealed industrial drive applications.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The VACONX4C50075C is an AC variable-speed drive produced by Danfoss for the Low Voltage VACON X Drives series. It interfaces between a plant’s three-phase power system and the motor, delivering a controlled output frequency so automated machinery can start, stop, and run at commanded speeds without mechanical throttling. The product serves as a compact motor controller that fits directly onto equipment exposed to washdown or outdoor environments common in industrial automation.
The drive accepts an input of 575 Vac from a three-phase supply, and its front-end rectifier tolerates line deviations of ±15% without derating. A sealed aluminum housing carries an ingress protection rating of IP66, preventing hose-directed water and dust from reaching the electronics. Inside this housing, the dynamic brake circuit activates when the DC link reaches 970 Vdc, diverting excess energy to a resistor so rapid deceleration does not trip the inverter. The T1 frame measures 166 mm deep, 221 mm wide, and 306 mm high. With a mass of 6.35 kg, the unit can be fastened to machine frames without additional structural support.
For heavy-duty starts, the inverter delivers 5 HP at a high-overload current of 6.1 A. Applications with lighter acceleration demands can access 7.5 HP continuously at a low-overload current of 9 A. Protection against abnormal mains conditions is provided by an overvoltage trip at 1017 Vdc and an undervoltage trip at 497 Vdc, shutting down the drive before electrical stress becomes critical. The separate overload classes allow the drive to accommodate demanding startup loads as well as equipment that requires higher continuous output. Its voltage protection helps safeguard the power section when the DC link rises or falls beyond the permitted operating range.