4.95 based on 202 reviews

🙶 Great service, they have the parts i needed in stock. 🙷

B162 Danaher

Ask for Availability
No Hidden Fees Rush or Credit Card
No Tariffs On US Orders

Internal Product Review

The B162 is a Danaher Quadraline regenerative drive designed for continuous duty and protected by a NEMA 4/12 enclosure. Stable operation is supported by ±2% speed regulation and 150% overload capacity for 1 min. A strong choice for industrial installations requiring dependable regenerative drive performance.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The B162 regenerative drive is produced by Danaher and belongs to the Quadraline Regenerative Drives series. As a line-commutated unit, it converts single-phase AC power into controlled armature voltage while channeling energy returned from overhauling loads back to the supply. In industrial automation, this product regulates DC motor speed, maintains commanded torque, and recovers braking energy, promoting tighter process control and improved electrical efficiency.

Electrical compatibility centers on a single-phase input, and the drive withstands mains variations of ±10% in voltage and ±2 Hz in frequency without derating. Its short-term overload capacity is 150% for 1 minute, supporting high-inertia starts or rapid acceleration. The heat sink and current-limiting circuitry allow the converter to return to steady-state output immediately afterward. The cast chassis and gasketed cover meet the NEMA 4/12 enclosure rating, protecting the control electronics from dust, oil, and water splashes during operation. This protection allows placement on open production floors without an auxiliary cabinet, while the vertical orientation with terminals facing downward preserves convection airflow and provides clear drip paths.

Continuous-duty operation is maintained across a 30:1 armature-feedback speed range, and closed-loop error stays within ±2% from no load to full load. The thermal design supports full output at enclosed ambient temperatures up to 40 °C and at installation heights reaching 3,300 ft (1,000 m) without a change in performance. The internal power section is rated for continuous duty, so the converter can supply its rated current indefinitely when adequate airflow is available. A remote station supplies start, stop, and speed inputs. The control loop recognizes a normally open start contact and a normally closed stop circuit, and it can process a 12.25 VDC tachometer signal for higher-resolution speed feedback. Because local keypad hardware is omitted, all user interaction is routed through the external panel or PLC I/O, providing a consistent control arrangement across multiple drives.

Duty
Continuous
Enclosure Rating
NEMA 4/12
Frequency Tolerance
±2 Hz
Line Voltage Tolerance
±10%
Max Altitude
3300 ft (1000 m)
Max Enclosed Ambient
40 °C
Mounting Orientation
Vertical, Terminals Down
Operator Controls
Remote Station Required
Overload Capacity
150% for 1 min
Speed Range
30:1 (Armature Fb)
Speed Regulation
±2% (Armature Fb)
Start Contact
Normally Open
Stop Contact
Normally Closed
Supply Phase
1 Phase
Tach Input Voltage
12.25 VDC

Frequently Asked Questions about B162:

Q: What is the enclosure rating of the Danaher B162 drive?

A: The B162 has an enclosure rating of NEMA 4/12, protecting it against dust, splashing water, and some oil or coolant seepage.

Q: What type of duty cycle does the B162 support?

A: The B162 regenerative drive is designed for continuous duty cycles, suitable for long-term operation without interruption.

Q: What is the maximum ambient temperature allowed for the B162?

A: The maximum ambient temperature for safe operation of the B162 is 40°C when enclosed.

Q: What is the required mounting orientation for the B162?

A: This drive must be installed vertically with the terminals facing downward.

Q: What is the tach input voltage specification for the B162 drive?

A: The B162 accepts a tach input voltage of 12.25 VDC.