4.95 based on 202 reviews

🙶 a+ fast delivery 🙷

B160 Danaher

Ask for Availability
No Hidden Fees Rush or Credit Card
No Tariffs On US Orders

Internal Product Review

The B160 is a Danaher Quadraline regenerative drive designed for single-phase operation with 115/230 VAC input. Continuous duty and default speed control give the unit stable, predictable motor handling in demanding DC drive applications. NEMA 4/12 enclosure protection is a strong advantage for industrial installations.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The B160 regenerative drive is manufactured by Danaher as part of the Quadraline Regenerative Drives series. The unit is a DC motor controller that returns excess kinetic energy to the supply when a motor decelerates, so it supports energy-conscious positioning, conveying, and test stands within industrial automation. By combining armature regulation with selectable 50/100 VDC or 100/200 VDC field voltages, it can excite shunt fields connected to 115 V or 230 V mains. This drive suits installations that prefer a packaged regeneration solution rather than discrete hardware.

Input power is flexible: the controller accepts 115/230 VAC and operates on a single-phase line. A frequency window of 50/60 Hz with a tolerance of ±2 Hz keeps the bridge synchronized with common utility grids. Four field-selectable current limits of 2.5/5/7.5/10 A DC match the armature ratings of small to medium-frame motors, while an internal 20 A semiconductor fuse protects the rectifier against short circuits. Separate field taps supply either 50/100 VDC from a 115 V source or 100/200 VDC from a 230 V source, allowing proper magnetization without an external transformer. The drive supports continuous-duty service when the heat sink is mounted vertically to provide upward airflow.

The default operating mode is speed control, implemented with a 2 kΩ reference potentiometer that provides a 30:1 armature speed range. Closed-loop response keeps steady-state velocity within ±2% of the set value despite line or load changes. For transient demands, the drivetrain can absorb or regenerate up to 150% for 1 minute before timers impose current foldback. A gasketed NEMA 4/12 enclosure permits installation in areas exposed to washdown or dust and supports operation at altitudes up to 3,300 feet (1,000 meters) without derating. The drive must remain vertical during operation to maintain the required convection paths, and its continuous-duty ratings apply across the stated operating limits.

115v Field Voltage
50/100 VDC
230v Field Voltage
100/200 VDC
Ac Input Frequency
50/60 Hz ±2 Hz
Ac Input Voltage
115/230 VAC ±10%
Current Settings
2.5/5/7.5/10 A DC
Default Control Mode
Speed Control
Duty
Continuous
Enclosure Rating
NEMA 4/12
Fuse Rating
20 A
Input Phase
Single Phase
Max Altitude
3300 ft (1000 m)
Max Load Capacity
150% for 1 min
Mounting Orientation
Vertical
Potentiometer Value
2 kΩ
Speed Range (armature)
30:1
Speed Regulation (armature)
±2%

Frequently Asked Questions about B160:

Q: What are the accepted AC input voltage levels for the B160 regenerative drive?

A: The Danaher B160 supports an AC input voltage of 115 or 230 VAC with a ±10% tolerance.

Q: What is the maximum overload capacity and duty cycle of the B160 drive?

A: The B160 provides continuous operation and allows for a maximum load capacity of 150% for up to 1 minute.

Q: What type of enclosure rating does the B160 drive have?

A: This model is rated for NEMA 4/12 enclosures, offering protection against dust, splashing water, and non-corrosive liquids.

Q: What is the default control mode available on the Danaher B160?

A: The B160 drive's default control mode is speed control.

Q: What output current settings are selectable on the B160 regenerative drive?

A: This drive allows current settings to be selected at 2.5, 5, 7.5, or 10 A DC.