★★★★★
4.94 based on 219 reviews

🙶 Wake was very helpful in getting us a servo motor and drive for our tube mill line. This was the first tim... 🙷

XMS2-W0100ANN-01NETT0NNNN-S04RSN1NNNN0NN Bosch Rexroth Indramat

Ask for Availability
No Hidden Fees Rush or Credit Card
No Tariffs On US Orders

Internal Product Review

The XMS2-W0100ANN-01NETT0NNNN-S04RSN1NNNN0NN is a single-axis ctrlX DRIVE inverter suited for precise motion control applications. Multi-Ethernet communication with Sercos III support enables streamlined network integration and dependable real-time performance. Internal air cooling and Safe Torque Off provide effective thermal management and valuable machine safety, highlighting a well-engineered drive package.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The XMS2-W0100ANN-01NETT0NNNN-S04RSN1NNNN0NN is a power section module manufactured by Bosch Rexroth Indramat for the XMS2 ctrlX Drives series. This single-axis inverter regulates the speed and torque of synchronous or induction motors in distributed automation systems. It converts DC-link voltage from a shared supply into a modulated three-phase output for precise motor control. Its compact format supports installation in packaging, material-handling, and assembly equipment where several coordinated motion axes share a common power source.

Its architecture uses a single-axis power channel, allowing one motor to be driven by each power module without axis-splitting hardware. Network integration is handled through the Multi-Ethernet interface, which allows the required real-time fieldbus to be selected during system setup instead of restricting the module to one protocol. The activated Sercos III profile supports deterministic communication cycles for demanding servo applications. Thermal management relies on internal air cooling, which draws cabinet air across the heat sink without requiring external ducting. As a second-generation ctrlX device, the module uses updated power electronics while retaining compatibility with established engineering tools. The power section is supplied without a control panel, and the available option slots are not equipped because operator functions can be provided through a centralized human-machine interface.

The integrated Safe Torque Off circuit disables gate signals to the insulated-gate bipolar transistors, supporting PL e or SIL 3 stop functions without external safety relays. Because the module operates as an inverter, it receives power from a common DC-link supply and produces the controlled three-phase output required by the connected motor. Its IP20 enclosure supports DC 750 V operation, protecting against finger contact with live parts while requiring installation in a clean, dry cabinet. Command processing and feedback functions reside in the mating ctrlX DRIVE control section, which connects directly to the power base. The wiring kit does not include a motor connector set, allowing the plug type and cable length to be selected for the application. The module is also supplied without an auxiliary fan or an integrated brake resistor, so any required braking equipment must be provided elsewhere in the drive system.

Axis
Single-Axis
Communication Method
Multi-Ethernet
Communication Protocol
Sercos III
Control Panel
Without Control Panel
Control Section
ctrlX DRIVE
Cooling Method
Air, internal
Generation
Second Generation
Hardware Option
Not Equipped
Hardware Options
Not Equipped
Hardware Safety Option
Safe Torque Off
Motor connector set
Without motor connector set
Operation
Inverter
Other power section option
None
Product Group
ctrlX DRIVE
Protection Rating
IP20, DC 750 V

Frequently Asked Questions about XMS2-W0100ANN-01NETT0NNNN-S04RSN1NNNN0NN:

Q: What communication method does the XMS2-W0100ANN-01NETT0NNNN-S04RSN1NNNN0NN support?

A: This drive supports a communication method of Multi-Ethernet, allowing various network integrations.

Q: Which communication protocol is implemented in the XMS2-W0100ANN-01NETT0NNNN-S04RSN1NNNN0NN model?

A: The drive uses the Sercos III communication protocol for precise and synchronized automation control.

Q: What type of axis configuration does the XMS2-W0100ANN-01NETT0NNNN-S04RSN1NNNN0NN offer?

A: It is a single-axis inverter drive, suitable for applications requiring individual axis management.

Q: What cooling method is used by the XMS2-W0100ANN-01NETT0NNNN-S04RSN1NNNN0NN drive?

A: This model is equipped with internal air cooling, ensuring operating temperatures are maintained within the unit.

Q: What hardware safety option is available on the XMS2-W0100ANN-01NETT0NNNN-S04RSN1NNNN0NN drive?

A: A Safe Torque Off hardware safety option is featured, providing a safety function that disables motor torque.

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo