XCS2-W0070ARN-01AETT0NNNN-S04RSN1NNNN0NN
Wake Industrial LLC is not an authorized distributor of this product.
MPN: R914508595
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The XCS2-W0070ARN-01AETT0NNNN-S04RSN1NNNN0NN converter is manufactured by Bosch Rexroth Indramat. Part of the XCS Single Axis CtrlX Converters, it features a maximum DC bus power of 53 kW and an output current of AC 35, DC 38.2. The device measures 100mm in width and 196.5mm in depth. It weighs 5.8 kg.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The XCS2-W0070ARN-01AETT0NNNN-S04RSN1NNNN0NN is a ctrlX drive single-axis unit from Bosch Rexroth Indramat that is part of the Generation 2 drive systems. There are built-in features in the drive that meet the needs of industrial automation. The ctrlX drive is made with an air-cooling system inside and can handle a maximum output current of 70 A.
The XCS2-W0070ARN-01AETT0NNNN-S04RSN1NNNN0NN ctrlX DRIVE is protected by IP20 and can handle voltages between 200 V and 500 V in three phases, with a +/- 15% range. It was made so that the ctrlX DRIVE can be easily added to control systems that need efficient drive technology. It can be used in automation systems that need small and expandable drive options. The control area has a panel and is part of the ctrlX DRIVE family. The drive doesn't come with a motor adapter and can communicate over multiple Ethernets. Sercos III is the name of the communication system. Under its safety gear, the drive has a feature called "Safe Torque Off." It doesn't come with any extra hardware choices. It is possible to connect 26 A of mains current in the absence of a choke, and 34.6 A with one. 50 A mains fuse is required, and the circuitry within is AWG 6 wire size.
Without a choke, the XCS2-W0070ARN-01AETT0NNNN-S04RSN1NNNN0NN drive can handle a load of 18 kVA. With a choke, the drive can handle 25 kVA. When a choke is used, the power factor goes up to 0.87 from 0.52 when there is no choke. The ctrlX DRIVE works with control systems that are connected to a network. Safety features and communication choices are built in to meet the needs of system-level design. The drive is designed to work well with electricity all the time. Standard versions of the ctrlX DRIVE make it easy to integrate into systems.
Frequently Asked Questions about XCS2-W0070ARN-01AETT0NNNN-S04RSN1NNNN0NN:
Q: Why does XCS2-W0070ARN-01AETT0NNNN-S04RSN1NNNN0NN include integrated braking?
A: It ensures faster stopping during faults or emergency stops. This avoids overheating by dissipating excess energy internally.
Q: Do XCS2-W0070ARN-01AETT0NNNN-S04RSN1NNNN0NN require internal wiring AWG 6?
A: Yes, AWG 6 supports current handling up to 70 A. It ensures proper conductor sizing and minimizes power loss.
Q: How does XCS2-W0070ARN-01AETT0NNNN-S04RSN1NNNN0NN manage high input currents?
A: It uses rated fuse of 50 A with or without choke. This protects against overcurrent while supporting stable drive operation.
Q: Why do XCS2-W0070ARN-01AETT0NNNN-S04RSN1NNNN0NN have two load values?
A: Choke usage changes the electrical characteristics. It improves power factor and reduces harmonics, affecting connected load rating.
Q: Does XCS2-W0070ARN-01AETT0NNNN-S04RSN1NNNN0NN include hardware expansion options?
A: No, it includes only STO safety hardware. The other two hardware slots are not equipped for additional functions.