XCS2-W0070ARN-01AETT0NNNN-S03RSN1NNNN0NN Bosch Rexroth Indramat
Wake Industrial LLC is not an authorized distributor of this product.
MPN: R914504120
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
The Bosch Rexroth Indramat XCS2-W0070ARN-01AETT0NNNN-S03RSN1NNNN0NN is part of the XCS Single Axis ctrlX Converters series and uses ctrlX DRIVE control hardware. This single-axis converter supports Multi-Ethernet communication, has a maximum current of 70 amps, and runs on 3-phase AC voltage ranging from 200 to 500 volts. It features Safe Torque Off for safety, an integrated braking transistor and resistor, and achieves an IP20 degree of protection.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The XCS2-W0070ARN-01AETT0NNNN-S03RSN1NNNN0NN is a single-axis converter manufactured by Bosch Rexroth Indramat for the XCS Single Axis CtrlX Converters series. Supplied as Generation 2 hardware with an integral operator panel, it forms part of the ctrlX DRIVE platform and delivers regulated AC output to one servo or induction motor. Feedback and safety interfaces support communication with higher-level motion controllers. The converter is designed for installation inside a control cabinet, where it combines power conversion, axis control, and safety functions in a compact module for packaging, material-handling, and general automation equipment.
The power section accepts a three-phase input range of 200 to 500 V AC with a tolerance of +10% and −15%, allowing operation on common 230 V and 400 V networks without tap changes. Internal air cooling removes heat from the power electronics without requiring an external fan kit. Under continuous load, the inverter can deliver up to 70 A of motor current, providing capacity for medium-power axes and their acceleration demands. The IP20 enclosure protects against accidental contact with live parts but requires installation inside a closed cabinet. Power and control wiring are supported by the converter’s standard connection arrangement. Field communication is centralized through the Multi-Ethernet interface, allowing the converter to connect to compatible industrial Ethernet networks.
Axis logic executes directly on ctrlX DRIVE using the Standard runtime environment and the DRIVE Runtime functional scope. Deterministic motion data can be exchanged through Sercos III, supporting synchronized command and feedback cycles between the converter and motion controller. The internal DC bus includes an integrated braking transistor and braking resistor that dissipate regenerated energy produced when the connected motor decelerates. For personnel and machine protection, the converter provides Safe Torque Off (STO) through SafeMotion hardware option 1. This function removes torque-producing energy from the motor without requiring mechanical relays and supports stop category 0 operation. The integral operator panel provides local access to drive information, while the single-axis design keeps the power and control functions dedicated to one connected motor.
Frequently Asked Questions about XCS2-W0070ARN-01AETT0NNNN-S03RSN1NNNN0NN:
Q: What type of communication does the XCS2-W0070ARN-01AETT0NNNN-S03RSN1NNNN0NN converter offer?
A: The XCS2-W0070ARN-01AETT0NNNN-S03RSN1NNNN0NN supports Multi-Ethernet communication for flexible connectivity options.
Q: What power section option is included in the XCS2-W0070ARN-01AETT0NNNN-S03RSN1NNNN0NN?
A: This model features an integrated braking transistor and braking resistor within its power section.
Q: How is the XCS2-W0070ARN-01AETT0NNNN-S03RSN1NNNN0NN cooled?
A: It uses an internal air cooling method to manage operating temperatures.
Q: What is the maximum current rating of the XCS2-W0070ARN-01AETT0NNNN-S03RSN1NNNN0NN?
A: The maximum output current of this converter is 70 A.
Q: What safety function is provided on the XCS2-W0070ARN-01AETT0NNNN-S03RSN1NNNN0NN converter?
A: This unit comes equipped with the Safe Torque Off (STO) safety function.