XCS2-W0023ARN-01AETT0NNNN-S05RSN2NNNN0NN Bosch Rexroth Indramat

Ask for Availability
No Hidden Fees Rush or Credit Card
No Tariffs On US Orders

Internal Product Review

The XCS2-W0023ARN-01AETT0NNNN-S05RSN2NNNN0NN is a Generation 2 ctrlX DRIVE single-axis converter from Bosch Rexroth Indramat. Multi-Ethernet communication and EtherCAT (SoE) support give the converter strong integration value in advanced motion architectures. A 3 x AC 200 to 500 V input range with Safe Torque Off (STO) makes this model a capable and safety-focused drive solution.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The XCS2-W0023ARN-01AETT0NNNN-S05RSN2NNNN0NN is a single-axis converter produced by Bosch Rexroth Indramat within the XCS Single Axis ctrlX Converters series. As a Generation 2 ctrlX DRIVE power module, it connects the supply network to a compatible servo or induction motor. The converter supplies regulated three-phase energy so automated equipment can control motor speed, position, and torque with cycle-to-cycle consistency. Its single-axis design combines the power stage and embedded control functions in a compact unit intended for installation inside an industrial control cabinet.

The device accepts a supply of 3 × AC 200 to 500 V (+10%/-15%) and can deliver up to 23 A through the motor terminals. Its Multi-Ethernet interface supports PROFINET, EtherNet/IP, and other compatible industrial networks through shared communication hardware. A dedicated EtherCAT interface using Servo Drive Profile over EtherCAT supports rapid cyclic data exchange with the machine controller. The IP20-rated enclosure protects against accidental contact with hazardous internal parts and requires installation within a suitable cabinet. Functional safety is provided by Safe Torque Off (STO), which disables the gate-drive signals to the power transistors when the corresponding safety input is activated. SafeMotion functions are also available through the first installed hardware option, allowing supported motion-safety tasks to run within the drive platform.

Thermal management uses internal air cooling to move cabinet air across the heat sink and remove heat from the power electronics. Adequate cabinet ventilation and clearance around the air passages are necessary to maintain proper airflow during continuous operation. An integrated braking transistor and braking resistor absorb regenerated energy when the connected motor decelerates, reducing voltage rise in the DC bus. Parameters and operating information are accessible through a front-mounted operator panel, which provides local access to common drive settings and status data. The embedded ctrlX DRIVE control platform runs the DRIVE Runtime functional scope and coordinates motor regulation, safety processing, and network communication. The output terminals are supplied without a motor connector set, allowing the connection hardware to be selected for the cable and motor used in the application.

Additional Design Features
None
Communication Type
Multi-Ethernet
Control Hardware
ctrlX DRIVE
Cooling Method
Air, internal
Degree of Protection
IP20
Description
ctrlX DRIVE, Single-axis converter, Generation 2
Export License Requirement
No (maximum output < 599 Hz)
Hardware Option 2 Detail
Not equipped
Hardware Option 3 Detail
Not equipped
Input Voltage
3 x AC 200 ... 500 V +10% -15%
Maximum Current
23 (A)
Motor Connector Set
Without motor connector set
Panel Option
With panel
Power Section Option Detail
Integrated braking transistor/braking resistor
Protocol
EtherCAT (SoE)
Runtime Environment
Standard
Runtime Functional Scope
DRIVE Runtime
Runtime Release Status
Current release
Runtime Version Detail
Version 05 (XCS2)
SafeMotion Functional Scope
Hardware option 1 SafeMotion
Safety Function
Safe Torque Off (STO)
Technology Function App
None

Frequently Asked Questions about XCS2-W0023ARN-01AETT0NNNN-S05RSN2NNNN0NN:

Q: What communication type is supported by the XCS2-W0023ARN-01AETT0NNNN-S05RSN2NNNN0NN converter?

A: The XCS2-W0023ARN-01AETT0NNNN-S05RSN2NNNN0NN supports a multi-Ethernet communication type for flexible industrial network integration.

Q: What input voltage range is required for the XCS2-W0023ARN-01AETT0NNNN-S05RSN2NNNN0NN?

A: This converter accepts a 3-phase AC input voltage ranging from 200 to 500 V with a tolerance of +10% to -15%.

Q: What cooling method does the XCS2-W0023ARN-01AETT0NNNN-S05RSN2NNNN0NN use?

A: The cooling method utilized by this model is internal air cooling.

Q: What safety function is provided by the XCS2-W0023ARN-01AETT0NNNN-S05RSN2NNNN0NN?

A: The XCS2-W0023ARN-01AETT0NNNN-S05RSN2NNNN0NN features Safe Torque Off (STO) as its safety function.

Q: Does the XCS2-W0023ARN-01AETT0NNNN-S05RSN2NNNN0NN have a braking transistor or resistor included?

A: This converter includes an integrated braking transistor and braking resistor in its power section.