VT-VRPA1-52-1X/ Bosch Rexroth Indramat
Wake Industrial LLC is not an authorized distributor of this product.
MPN: R900952205
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
Current response time:
6 Minutes
20 Seconds
The Bosch Rexroth Indramat VT-VRPA1-52-1X/ is part of the VT-VRPA Electric Amplifiers series and operates with a 24 V DC power supply, consuming 37 W. This amplifier features a current rating of 1.5 A, setpoint input of ±10 V, and a potentiometer of 10 kΩ. It includes seven modular spacings on the front panel and supports a valve solenoid load of 2.7 A at 40 VA.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
Bosch Rexroth Indramat’s VT-VRPA1-52-1X/ is an analog amplifier card in the VT-VRPA Electric Amplifiers series. Installed in a valve control rack, the card modulates coil current so a proportional hydraulic valve follows a voltage command from the PLC or motion controller. By converting low-level setpoints into regulated load current, it provides the interface between electronic command circuits and the inductive solenoids used in industrial automation. This arrangement supports repeatable valve response in systems that use proportional hydraulics for position, force, or flow control.
The card draws a continuous 1.5 A from a 24 V DC supply, and its internal losses can reach 37 W during full-scale operation. It mounts in a European-format rack and occupies a front-panel width of 7 modular spacings, allowing predictable slot allocation in multi-axis installations. This layout helps keep rack planning straightforward when several control cards share the same enclosure. Input conditioning accepts differential commands, and the zero trimmer provides ±5% offset correction. An onboard ±15 V rail feeds external position sensors, while the 10 kΩ feedback potentiometer can be biased with a 10 mA source for linear position feedback. The 100 kΩ setpoint resistance minimizes loading on upstream analog outputs.
The amplifier accepts a differential command range of ±10 V, which it interprets as full stroke. If an internal fault is detected, the error output can sink 100 mA to signal the host controller. The power stage supports a maximum solenoid load of 2.7 A / 40 VA, and a 4700 µF/63 V DC capacitor helps smooth supply disturbances during rapid current changes. The command input, fault output, and current stage support stable analog valve control during changing load conditions. Because the error output is available to the host control system, abnormal conditions can be monitored without adding a separate supervisory module.
Frequently Asked Questions about VT-VRPA1-52-1X/:
Q: What is the power supply voltage for the VT-VRPA1-52-1X/?
A: The VT-VRPA1-52-1X/ amplifier requires a 24 V DC power supply for operation.
Q: What is the current rating of the VT-VRPA1-52-1X/ amplifier?
A: This amplifier is rated at a maximum current of 1.5 A.
Q: What setpoint input voltage range does the VT-VRPA1-52-1X/ accept?
A: The VT-VRPA1-52-1X/ supports setpoint input signals of ±10 V.
Q: What potentiometer value is recommended for the VT-VRPA1-52-1X/?
A: A potentiometer with a resistance of 10 kΩ can be used with this model.
Q: How many modular spacings are available on the front panel of the VT-VRPA1-52-1X/?
A: On the front panel, the VT-VRPA1-52-1X/ provides 7 modular spacings for configuration.