4.94 based on 219 reviews

🙶 Wake was very helpful in getting us a servo motor and drive for our tube mill line. This was the first tim... 🙷

VT-MSPA 1-1-12A-V0-0 Bosch Rexroth Indramat

MPN: R900702060

The Bosch Rexroth Indramat VT-MSPA 1-1-12a-V0-0 is part of the VT-MSPA Drives series and has a nominal operating voltage of 24 V DC with a power consumption under 48 Watts. Designed with 12 spring-type terminals and IP20 protection class, it features a solenoid current of 2.7 Amps and weighs 0.14 kilograms. The device uses an external 3.15 Amp time-lag fuse and supports a cable length up to 50 meters.

No Hidden Fees Rush or Credit Card
No Tariffs On US Orders

Internal Product Review

The VT-MSPA 1-1-12a-V0-0 is a Bosch Rexroth Indramat drive module designed for stable 24 V DC operation with IP20 protection. A 12 spring-type terminal connection and start-up time under 1 s support clean panel wiring and quick commissioning in control cabinets. Current demand below 2 A keeps integration straightforward, making this unit a dependable choice for compact industrial drive applications.

Sell Part Have a part to sell?
Warranty Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The VT-MSPA 1-1-12a-V0-0 is a compact electronic drive module from Bosch Rexroth Indramat in the VT-MSPA Drives series. It adapts a 24 V DC control supply to the current levels required by industrial solenoid loads, allowing precise actuation of field devices in automated machinery. By presenting dedicated input and output terminals, the unit occupies minimal panel space while contributing current regulation and protection functions to low-voltage automation circuits.

Its field connections are arranged on 12 spring-type terminals, giving quick clamp access for signal and power wiring. The module expects a stable bus voltage of 24 V DC, and conductors may be routed up to 50 m (1.5 mm²) without signal loss. The housing meets the IP20 protection class, so it must reside inside a closed electrical cabinet. Under worst-case demand, the electronics draw <48 W, which helps with power-supply sizing and cabinet thermal management. Input circuitry presents a 200 kΩ voltage resistance and a 100 Ω current load resistance, ensuring compatibility with standard PLC analog outputs. Minimum load impedance of 1000 Ω prevents overcurrent on voltage-driven channels, and residual ripple is limited to 2.5 Vpp for consistent actuator behavior.

Operating requirements remain modest: total current consumption stays below <2 A, and inrush peaks under 4 A before settling. A safety fuse rated at 3.15 A time-lag should be installed on the supply line to isolate faults. The output stage can deliver 2.7 A of regulated solenoid current, reaching its target in <1 s after power is applied, so machine sequences start promptly. An upper voltage limit of 36 V protects semiconductors, while the 0.14 kg assembly adds little weight to the DIN rail.

Cable Length
50 m (1.5 mm²)
Connection Type
12 Spring-Type Terminals
Current Consumption
<2 A
Current Input Load Resistance
100 Ω
External Fuse
3.15 A Time-Lag
Minimum Load Impedance
1000 Ω
Nominal Operating Voltage
24 V DC
Power Consumption
<48 W
Protection Class
IP20
Residual Ripple
2.5 Vpp
Solenoid Current
2.7 A
Start-up Time
<1 s
Switch-on Current
<4 A
Upper Voltage Limit
36 V
Voltage Input Resistance
200 kΩ
Weight
0.14 kg

Frequently Asked Questions about VT-MSPA 1-1-12A-V0-0:

Q: What is the nominal operating voltage of the VT-MSPA 1-1-12a-V0-0 drive?

A: The VT-MSPA 1-1-12a-V0-0 has a nominal operating voltage of 24 V DC.

Q: What is the maximum cable length supported by the VT-MSPA 1-1-12a-V0-0?

A: This model is designed for use with cable lengths up to 50 meters using 1.5 mm² wire.

Q: How many and what type of connection terminals does the VT-MSPA 1-1-12a-V0-0 provide?

A: The VT-MSPA 1-1-12a-V0-0 is equipped with 12 spring-type terminals for electrical connections.

Q: What level of environmental protection does the VT-MSPA 1-1-12a-V0-0 offer?

A: With a protection class of IP20, the VT-MSPA 1-1-12a-V0-0 is protected against solid objects larger than 12.5 mm but not against water.

Q: What type of external fuse should be used with the VT-MSPA 1-1-12a-V0-0?

A: This drive uses a recommended external time-lag fuse rated at 3.15 A.

  • vt-mspa 1-1-12a/v0/0
  • VT MSPA 1 1 12a V0 0
Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo