Internal Product Review

The VT-HNC100-4-30/E-I-00-G04 is a Bosch Rexroth Indramat digital axis controller configured for 4 hydraulic axes. Signal handling is especially strong, with 2 analog voltage inputs and 2 analog voltage outputs per axis supporting precise hydraulic control. Incremental encoder processing up to 250 kHz makes this controller a very capable choice for responsive multi-axis motion applications.

Sell Part
Have a part to sell?
Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The VT-HNC100-4-30/E-I-00-G04 is a digital axis controller manufactured by Bosch Rexroth Indramat for the VT-HNC Digital Axis Controllers series. Classified as an HNC100 unit, this version coordinates four hydraulic axes and provides local position and force control. It operates without a bus connection, so its control functions do not depend on a higher-level fieldbus. Feedback, command, and drive signals are integrated into one rack module, providing closed-loop motion control for presses, die-casting machines, and plastic injection lines.

Each axis accepts two analog current inputs per axis through a front end with an input resistance of 200 kΩ ±5%, which minimizes the load placed on upstream signal conditioners. The current input converter provides a resolution of 5 µA, allowing the controller to detect small changes in incoming current signals. The voltage digital-to-analog converter produces output increments as fine as 1.25 mV, supporting precise pressure or velocity corrections. Current-mode command lines can drive valves or boosters when the receiving circuit remains below a maximum load of 500 Ω. Keeping the connected load within this limit helps prevent saturation of the onboard amplifiers and maintains the intended loop gain.

The logic layer provides 11 digital I/O points per axis, allowing each controlled axis to exchange status and command signals with connected machine devices. The backplane supports up to 20 digital outputs in total for operating solenoids, relays, and similar loads. Position feedback from incremental encoders is accepted at carrier frequencies up to 250 kHz, permitting high-speed axis tracking without missed counts. An auxiliary supply provides transducers with a stabilized output of 5.25 V ±1% and makes 400 mA available for connected sensors. Each axis also includes two analog voltage inputs and two analog voltage outputs for hydraulic feedback and command signals. These interfaces are contained within a compact cabinet-mounted module that supports multi-axis hydraulic control without requiring separate signal-processing hardware.

Analog Current Inputs
2 Per Axis
Analog Current Outputs
1 Per Axis
Analog Input Resistance
200 kΩ ±5%
Analog Output Resolution
1.25 mV
Analog Voltage Inputs
2 Per Axis
Analog Voltage Outputs
2 Per Axis
Axis Version
Version for 4 hydraulic axes
Bus Connection
Without Bus Connection
Current Input Resolution
5 μA
Current Output Load
500 Ω Max
Digital I/o Per Axis
11
Encoder 24 V Supply
500 mA
Encoder Supply Current
400 mA
Encoder Supply Voltage
5.25 V ±1%
Incremental Max Frequency
250 kHz
Max Digital Outputs
20
Product Series
Digital NC control HNC100
Voltage Input Resolution
5 mV
Voltage Output Load
1 kΩ Min

Frequently Asked Questions about VT-HNC100-4-30/E-I-00-G04:

Q: How many hydraulic axes can the VT-HNC100-4-30/E-I-00-G04 control?

A: The VT-HNC100-4-30/E-I-00-G04 is designed for four hydraulic axes.

Q: How many analog current inputs are available per axis on the VT-HNC100-4-30/E-I-00-G04?

A: Each axis supports two analog current inputs on this model.

Q: What is the analog output resolution on the VT-HNC100-4-30/E-I-00-G04?

A: The analog output resolution of this axis controller is 1.25 mV.

Q: What is the maximum current output load supported by the VT-HNC100-4-30/E-I-00-G04?

A: The maximum load for current outputs is 500 Ω.

Q: Does the VT-HNC100-4-30/E-I-00-G04 include a bus connection?

A: This device does not feature a bus connection as part of its configuration.