Rexroth, Indramat, Bosch Digital Axis Control in the VT-HNC100 Series. This Digital Axis Control features 1 Hydraulic Axis, PROFIBUS DP Bus Connection and a Incremental/SSI Position Transducer.

VT-HNC100-1-3X-P-I-00-000

  • {{ 'Rated ' + avg.toFixed(1) + ' (' + ratingCount + ' total ratings)' }}
  • {{ message }}
Rexroth, Indramat, Bosch Digital Axis Control in the VT-HNC100 Series. This Digital Axis Control features 1 Hydraulic Axis, PROFIBUS DP Bus Connection and a Incremental/SSI Position Transducer.

Warranty
1 Year Wake Industrial Warranty Included
Shipping
Worldwide shipping via DHL, UPS, and Fedex
Exchange
Call to find out about our exchange credit for your defective unit.
Sell Us Your Surplus
Have a VT-HNC100-1-3X-P-I-00-000 to sell?
To Speak to a sales representative for pricing and lead time:

Product Description

Technical data reveals that the operating voltage of the VT-HNC100-1-3X-P-I-00-000 is 18 to 36 VDC, and it has power consumption of 8 W (plus power for connected sensors/actuators).  The features of the processor and memory of the VT-HNC100-1-3X-P-I-00-000 are 16/32-bit MC68376 Memory Flash EPROM 1 MB; EEPROM 8 KB; RAM 256 KB (main memory) respectively.

The VT-HNC100-1-3X-P-I-00-000 has 8, 16 and 24 digital inputs and digital outputs, and there are a total of 3 analogue inputs i.e. voltage inputs, current inputs and impedance inputs. Not all the input channels are used simultaneously while operating the VT-HNC100-1-3X-P-I-00-000. Both the current input and the voltage input are provided with a common pin, so that only one voltage input is use at a time. No internal protective circuits with capacitors and diodes may be used due to the high resistance inputs. For this reason, while connecting the analogue signals to the inputs, connect the protective features including EMC protection, shield and the signal filter externally to the incoming circuit.

Below are the features of analogue outputs of the VT-HNC100-1-3X-P-I-00-000

 Voltage outputs

  • There are a total of 4 channels  
  • Output voltage: –10 V to +10 V (max. –10.7 V to +10.7 V)
  • Output current : ±10 mA
  • Load 1 kΩ

Current outputs

  • Number of channels: 2
  • Output current normalised 4 mA to 20 mA,  not normalised ±23 mA
  • Load 500 Ω

Residual ripple content ±60 mV (without noise)

Resolution 1.25 mV

Non-linearity

  • within the range of –9.5 V to +9.5 V 15 mV
  • within the range of –10 V to –9.5 V and +9.5 V to +10 V 35 mV
  • VT HNC100 1 3X P I 00 000
  • VT HNC100-1-3X/P-I-00/000
  • VT-HNC-100-1-3X/P-I-00/000
  • VT-HNC100-1-3X/P-I-00/000
  • VT-HNC1OO-1-3X/P-I-OO/OOO
  • VTHNC10013XPI00000

VT-HNC100-1-3X-P-I-00-000 Technical Specifications

Product: VT-HNC100
Hydraulic Variant: 1 Hydraulic Axis
Component Series: 30 to 39
Bus Connection: PROFIBUS DP
Position Transducer: Incremental/SSI
Service Interface: No fitting
Option: Without synchronization