VT-HNC100-1-30/S-I-30/000
Wake Industrial LLC is not an authorized distributor of this product.
MPN: R901234133
No Tariffs On US Orders- Straightforward Pricing: No Rush Fees, No Credit Card Fees
-
In-Stock, Ships 3-5 Days
The VT-HNC100-1-30/S-I-30/000 is a digital axis controller manufactured by Bosch Rexroth Indramat. Part of the VT-HNC Digital Axis Controllers series, it features a voltage output range of -10V to +10V and an adjustable SSI transducer data width of up to 28 bits. The controller also includes optional bus interfaces such as PROFIBUS DP, CANopen, and INTERBUS-S.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The VT-HNC Digital Axis Controllers range includes the Bosch Rexroth Indramat VT-HNC100-1-30/S-I-30/000, which operates precisely in industrial motions.
The controller can adjust to different industrial power supply by operating with a voltage between 18 and 36 VDC. When normalizing signals, the output current ranges from 4 mA to 20 mA, and it achieves a maximum non-normalized output of ±23 mA. The digital output delivers 1.25 millivolt precision to precisely control connected devices. The device produces output voltage from -10 V up to +10 V as it extends from -10.7 V to +10.7 V limits. The product works with regular devices due to a 500-ohm load resistance setting for current outputs. The transducer delivers digital LOW signals when voltage enters within the range of 0 to 1 V and produces digital HIGH when voltage falls between 2.8 and 5.5 V. The output signals produce -0.8 mA at 0 V as LOW and +0.8 mA at 5 V as HIGH signals for fast measurement systems up to 250 kHz. You can adjust the SSI transducer data width as high as 28 bits via Gray Code according to your position measurement requirements.
The controller has both RS232 and standard serial protocols at 9.6 KBaud for data exchange plus PROFIBUS DP (up to 12 MBaud), CANopen, and INTERBUS-S to connect with different systems. Within its -9.5 V to +9.5 V range the controller shows an analog voltage input error of 15 mV while approaching the ±10 V limits it requires 35 mV. The electronic controller provides +5 VDC power supply voltage that stays within ±5% of the actual voltage while delivering up to 200 mA of load current. This controller connects to different position feedback systems for both SSI and TTL-based position transducers.
Frequently Asked Questions about VT-HNC100-1-30/S-I-30/000:
Q: What voltage ranges can the VT-HNC100-1-30/S-I-30/000 handle?
A: The VT-HNC100-1-30/S-I-30/000 can operate within a voltage range of 18 to 36 VDC, making it versatile for different industrial power supplies.
Q: What is the maximum output current of the VT-HNC100-1-30/S-I-30/000?
A: This controller provides a maximum normalized output current of 20 mA and can reach a non-normalized maximum of ±23 mA.
Q: What type of precision does the VT-HNC100-1-30/S-I-30/000 deliver in its digital outputs?
A: It delivers a high precision of 1.25 millivolts in its digital outputs, ensuring accurate control of connected devices.
Q: Can the VT-HNC100-1-30/S-I-30/000 interface with different communication protocols?
A: Yes, it supports RS232, standard serial protocols at 9.6 KBaud, PROFIBUS DP (up to 12 MBaud), CANopen, and INTERBUS-S, offering flexible connectivity options.
Q: What are the key features of the VT-HNC100-1-30/S-I-30/000’s output signal handling?
A: The device handles digital LOW signals within 0 to 1 V and HIGH between 2.8 to 5.5 V, with output signals of -0.8 mA at 0 V and +0.8 mA at 5 V for fast measurement systems up to 250 kHz.