VT-HNC100-1-30-P-I-E0-000

  • {{ 'Rated ' + avg.toFixed(1) + ' (' + ratingCount + ' total ratings)' }}
  • {{ message }}
Rexroth, Indramat, Bosch Digital Axis Control in the VT-HNC100 Series. This Digital Axis Control features 1 Hydraulic Axis, PROFIBUS DP Bus Connection and a Incremental/SSI Position Transducer.

VT-HNC100-1-30-P-I-E0-000

  • {{ 'Rated ' + avg.toFixed(1) + ' (' + ratingCount + ' total ratings)' }}
  • {{ message }}
Rexroth, Indramat, Bosch Digital Axis Control in the VT-HNC100 Series. This Digital Axis Control features 1 Hydraulic Axis, PROFIBUS DP Bus Connection and a Incremental/SSI Position Transducer.

Warranty
1 Year Wake Industrial Warranty Included
Shipping
Worldwide shipping via DHL, UPS, and Fedex
Exchange
Call to find out about our exchange credit for your defective unit.
Sell Us Your Surplus
Have a VT-HNC100-1-30-P-I-E0-000 to sell?
To Speak to a sales representative for pricing and lead time:

Product Description

The VT-HNC100-1-30-P-I-E0-000 has NC language with subprogram techniques and conditional jumps. The control axis has its own NC program for the function sequences. You can parameterize various HNC100 with the help of the local bus.

The operating voltage of the VT-HNC100-1-30-P-I-E0-000 is 18 to 36 VDC, and has a power consumption of 8 W (plus power for connected sensors/actuators). The process and memory required for operating the VT-HNC100-1-30-P-I-E0-000 are 16/32-bit MC68376 and Flash EPROM 1 MB; EEPROM 8 KB; RAM 256 KB (main memory) respectively! The process interfacing of the VT-HNC100-1-30-P-I-E0-000  consist of  8, 16 or 24 digital inputs and outputs each, Profibus DP, CANopen or INTERBUS-S for communication with a PLC. It has three analogue inputs. Following are the features of the voltage inputs with differential inputs:

  • There are a total number of 4 channels
  • Input voltage ranges from +10 V to –10 V which is measurable upto (max. +15 V to –15 V).  It’s input resistance is RI 200 kΩ ±2 %
  • Resolution 5 mV
  • Non-linearity < 10 mV
  • Calibration tolerance 2) max. 40 mV (with factory setting)

The current inputs of the VT-HNC100-1-30-P-I-E0-000 has following features

  • Same as the voltage inputs it has four channels for the current inputs
  • Input current - 4 mA to 20 mA
  • Input resistance - 100 Ω ±0.2 %
  • Resistance between Pin “Iin 1 –“ and “analog_GND“ 0 to 500 Ω
  • Power loss 0.1 to 0.4 % (at 500 Ω between pin ”Iin 1 –“ and “analog_GND“)
  • Resolution 5 µA

Lastly, the impedance inputs of the control axis are:

  • Number of channels : 4
  • Input voltage:  –10 V to +10 V
  • Input resistance: > 10 MΩ
  • Resolution 5 mV
  • Non-linearity < 10 mV
  • Calibration tolerance 2) max. 40 mV (with factory setting)
  • VT HNC100 1 30 P I E0 000
  • VT HNC100-1-30/P-I-E0/000
  • VT-HNC-100-1-30/P-I-E0/000
  • VT-HNC100-1-30/P-I-E0/000
  • VT-HNC1OO-1-3O/P-I-EO/OOO
  • VTHNC100130PIE0000

VT-HNC100-1-30-P-I-E0-000 Technical Specifications

Product: VT-HNC100
Bus Connection:
Hydraulic Variant: 1 Hydraulic Axis
Component Series: 30
Bus Connection: PROFIBUS DP
Position Transducer: Incremental/SSI
Service Interface: TCP/IP
Option: Without synchronization