The VT-HNC100-1-23/W-08-C-0 digital axis controller features a current consumption of 1.23 amps, a rated voltage of ±100 volts, and IP20 ingress protection. Part of the VT-HNC Digital Axis Controllers by Bosch Rexroth Indramat, it has a DIN rail mounting type and a durable stainless steel housing.
To contact sales for pricing and lead time:
Payment Methods
Shipping Methods
Our Credentials
Product Description:
The VT-HNC100-1-2X/W-08-C-0 is a digital axis controller made by Bosch Rexroth Indramat. It features PDT1 position control and PIDT1 pressure/force control. The VT-HNC digital axis controller includes dynamic error monitoring and cable break detection for industrial applications requiring precise axis control.
The VT-HNC100-1-2X/W-08-C-0 digital axis controller consumes 8 W of power excluding connected sensors and operates on 18 to 36 VDC power supply. It features a 16/32-bit MC68376 processor, 1 MB flash EPROM, 256 KB RAM and 8 digital I/O. The VT-HNC100 digital controller includes CANopen for bus interfacing and has 4 analogue voltage input channels with ±10 V range while it has 4 analogue current inputs with 4 mA to 20 mA range. The input resistance for voltage channels is 200 kilo Ω ±2% and voltage input resolution of 5 mV with <10 mV. The VT-HNC digital axis controller’s calibration tolerance for input voltage is max 40 mV. The VT-HNC digital axis controller has current input resistance of 100 Ω ±0.2% and current input resolution 5 μA. It has 4 analogue impedance inputs with ±10 V range and impedance input resistance is >10 MΩ. It offers 4 analogue voltage outputs with ±10 V range and the voltage output current is ±10 mA with 1 kΩ load. The < The <
Frequently Asked Questions about VT-HNC100-1-23/W-08-C-0:
Q: What role does CANopen play in the VT-HNC100-1-2X/W-08-C-0?
A: CANopen provides real-time data exchange and networked communication, ensuring seamless integration with industrial automation systems.
Q: How does the dynamic error monitoring improve system performance?
A: It continuously tracks control deviations, minimizing errors and ensuring stable operation by quickly detecting faults.
Q: What is the significance of the MC68376 processor in this controller?
A: The 16/32-bit MC68376 processor enables fast computational performance, ensuring rapid response times for motion control tasks.
Q: How does the 5 µA current input resolution benefit precision applications?
A: The high resolution allows precise signal interpretation, ensuring accurate force and motion control in industrial systems.
Q: Why does the VT-HNC100-1-2X/W-08-C-0 support both RS232 and Profibus DP?
A: These interfaces enable versatile communication, allowing integration with legacy and modern industrial networks for enhanced operational flexibility.