4.95 based on 202 reviews

🙶 Wake Ind. did a great job with very fast service getting us a motor driver to repair our critical robot sy... 🙷

VT-HNC100-1-1X-260 Bosch Rexroth Indramat

MPN: R900927936

No Tariffs On US Orders
  • Rated 4.5 (55 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat VT-HNC100-1-1X-260 is part of the VT-HNC Digital Axis Controllers series and is designed for controlling a single hydraulic axis. It features a 16/32-bit MC68376 processor, 1 MB flash memory, and 256 KB RAM. The controller offers 4 current input channels with 5 μA resolution and 4 voltage output channels with an output resolution of 1.25 mV.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The VT-HNC100-1-1X-260 is a digital axis controller produced by Bosch Rexroth Indramat within the VT-HNC Digital Axis Controllers series. It is intended to manage closed-loop motion on hydraulic machinery by converting analog or digital command variables into proportional valve currents and feedback-based corrections. Through internal signal processing, the unit coordinates position, velocity, and pressure targets so a single hydraulic cylinder can follow programmed trajectories in presses, metal-forming stations, or test rigs.

This model controls 1 hydraulic axis, so its internal resources are allocated for a single motion channel. The unit provides 4 current input channels as differential analog inputs, and each channel presents a precise 100 Ω input resistance to the connected device to help limit loading effects. The converter resolves those input signals down to 5 µA, allowing small command changes to be recognized by the control loop. Two current outputs drive proportional valves, while four voltage inputs and four voltage outputs handle transducer feedback and command values. The voltage output stage steps at 1.25 mV, so command references can be trimmed in fine increments. Additional analog inputs have more than 10 MΩ of impedance, and the voltage inputs are measured to 5 mV with a 200 kΩ front-end resistor network for standard ±10 V sensors.

An output ripple of ±60 mV is the peak-to-peak noise superimposed on the commanded voltage, which is low enough to avoid dither in most servo valves. Program code is retained in an EPROM of 8 KB, while user parameters are stored in a flash array of 1 MB; fast data buffering is handled by 256 KB of RAM. All tasks are scheduled by the 16/32-bit MC68376 processor, so axis calculations, communication, and diagnostics run deterministically within the 8 W power budget.

Axis Version
Version for 1 hydraulic axis
Component Series
1
Current Input Channels
4
Current Input Resistance
100 Ω ±0.2%
Current Input Resolution
5 µA
Current Output Channels
2
Eprom
8 KB
Flash Memory
1 MB
Impedance Input Resistance
>10 MΩ
Output Resolution
1.25 mV
Output Ripple
±60 mV
Power Consumption
8 W
Processor
16/32-bit MC68376
Product Series
Digital NC control HNC100
Ram
256 KB
Voltage Input Channels
4
Voltage Input Resistance
200 kΩ ±2%
Voltage Input Resolution
5 mV
Voltage Output Channels
4
  • VT-HNC100-1-1X/260
  • VTHNC10011X260
  • vt-hnc100-1-1x-260
  • vt-hnc100-1-11-260
  • vt-hnc100-1-12-260
  • vt-hnc100-1-13-260
  • vt-hnc100-1-14-260
  • vt-hnc100-1-15-260
  • vt-hnc100-1-16-260
  • vt-hnc100-1-17-260
  • vt-hnc100-1-18-260
  • vt-hnc100-1-19-260

Frequently Asked Questions about VT-HNC100-1-1X-260:

Q: How many hydraulic axes does the VT-HNC100-1-1X-260 controller support?

A: The VT-HNC100-1-1X-260 controller is configured for use with a single hydraulic axis.

Q: How many voltage input channels are present on the VT-HNC100-1-1X-260?

A: This model includes 4 voltage input channels, enabling connectivity with multiple analog voltage sources.

Q: What is the current input resolution of the VT-HNC100-1-1X-260?

A: The current input resolution is 5 μA, allowing for precise current measurement signals.

Q: How many voltage output channels does the VT-HNC100-1-1X-260 offer?

A: The VT-HNC100-1-1X-260 provides four voltage output channels for driving external devices.

Q: What type of processor is used in the VT-HNC100-1-1X-260 axis controller?

A: This controller is built with a 16/32-bit MC68376 processor.


Internal Product Review

  • ‘‘The VT-HNC100-1-1X-260 is a digital axis controller for 1 hydraulic axis, and the configuration feels especially well suited to precise hydraulic motion control. A 16/32-bit MC68376 processor with 1 MB flash memory gives the unit fast command execution and dependable control performance. Four voltage input channels and 5 mV voltage input resolution make the controller a strong choice for accurate signal handling.’’