4.95 based on 202 reviews

🙶 a+ fast delivery 🙷

VT-HNC100-1-1X-132-13 Bosch Rexroth Indramat

MPN: R900948392

No Tariffs On US Orders
  • Rated 4.6 (49 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat VT-HNC100-1-1X-132-13 is part of the VT-HNC Digital Axis Controllers series and is designed for controlling a single hydraulic axis. This controller features a 16/32-bit MC68376 processor, 1 MB flash memory, and 256 KB RAM with a maximum encoder frequency of 250 kHz. It operates with a power consumption of 8 watts and includes an RS232 serial interface.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The VT-HNC100-1-1X-132-13 is a digital axis controller produced by Bosch Rexroth Indramat for the VT-HNC Digital Axis Controllers series. It also belongs to the Digital NC control HNC100 product series. It coordinates one hydraulic axis by generating precise analog commands and evaluating feedback signals so that cylinders or valves can be positioned with repeatable accuracy in automated presses, plastic-processing machines, test rigs, and similar hydraulic equipment. The controller is intended for machines that depend on monitored feedback rather than open-loop hydraulic actuation.

Control performance begins with the MC68376 16/32-bit processor that executes closed-loop routines stored in 1 MB of flash, backed up by 256 KB of RAM and an 8 KB EEPROM for parameter retention. A maximum encoder frequency of 250 kHz lets the SSI interface handle 28-bit position words without missed counts. Analog measurement is digitized at 5 mV resolution, and communication with setup software is handled through an RS-232 port set to 9.6 kbaud. The unit draws only 8 W, easing cabinet thermal design, and it supplies sensors with 200 mA from its dedicated transducer output. Command outputs can drive ±10 mA, while two transistor stages source 50 mA for binary actuators. Current-loop inputs use a tightly controlled impedance, and voltage inputs rely on a 500 Ω burden resistor. The memory arrangement keeps operating routines and retained parameters separated inside the controller.

Signal quality is reinforced by an output resolution of 1.25 mV, permitting fine control across the calibrated span of ±10 V ±25 mV. On the feedback side, the strict 100 Ω ±0.2% input impedance stabilizes current-loop measurements. These signal characteristics support smooth command behavior and accurate response in closed-loop hydraulic control. Fine electrical granularity helps the unit regulate valve or cylinder motion without coarse command steps during positioning.

Axis Version
Version for 1 hydraulic axis
Component Series
1
Current Input Resistance
100 Ω ±0.2%
Current Output Load
500 Ω
Eeprom
8 KB
Flash Memory
1 MB
Max Encoder Frequency
250 kHz
Output Resolution
1.25 mV
Power Consumption
8 W
Processor
MC68376 16/32-bit
Product Series
Digital NC control HNC100
Ram
256 KB
Reference Voltage
±10 V ±25 mV
Serial Interface
RS232 (9.6 KBaud)
Ssi Data Width
28 bits
Switching Output Current
50 mA
Transducer Supply Current
200 mA
Voltage Input Resolution
5 mV
Voltage Output Current
±10 mA
  • VT-HNC100-1-1X/132/13
  • VTHNC10011X13213
  • vt-hnc100-1-1x-132-13
  • vt-hnc100-1-11-132-13
  • vt-hnc100-1-12-132-13
  • vt-hnc100-1-13-132-13
  • vt-hnc100-1-14-132-13
  • vt-hnc100-1-15-132-13
  • vt-hnc100-1-16-132-13
  • vt-hnc100-1-17-132-13
  • vt-hnc100-1-18-132-13
  • vt-hnc100-1-19-132-13

Frequently Asked Questions about VT-HNC100-1-1X-132-13:

Q: How many axes can the VT-HNC100-1-1X-132-13 digital axis controller manage?

A: The VT-HNC100-1-1X-132-13 is designed for controlling a single hydraulic axis in automation systems.

Q: What is the maximum encoder frequency supported by the VT-HNC100-1-1X-132-13 controller?

A: This model supports a maximum encoder input frequency of 250 kHz for precise position signal processing.

Q: How much flash memory is available on the VT-HNC100-1-1X-132-13 controller?

A: The VT-HNC100-1-1X-132-13 is equipped with 1 MB of flash memory, enabling onboard program and data storage.

Q: What is the voltage input resolution on the VT-HNC100-1-1X-132-13?

A: The device features a voltage input resolution of 5 mV, allowing for accurate analog signal measurement.

Q: Which processor is integrated into the VT-HNC100-1-1X-132-13 controller?

A: The VT-HNC100-1-1X-132-13 uses an MC68376 16/32-bit processor to manage digital control operations efficiently.


Internal Product Review

  • ‘‘The VT-HNC100-1-1X-132-13 is a Bosch Rexroth Indramat digital axis controller designed for 1 hydraulic axis and built around an MC68376 16/32-bit processor. High-response control is supported by a 250 kHz max encoder frequency and 1.25 mV output resolution, making the HNC100 platform an excellent choice for precise hydraulic motion applications.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo