The Bosch Rexroth Indramat VT-HNC100-1-1X-130-3 is part of the VT-HNC Digital Axis Controllers series and is designed for control of a single hydraulic axis. It features a 16/32-bit MC68376 processor, 256 KB RAM, 1 MB flash memory, and a 1.25 mV analog output resolution. The controller offers a current input resistance of 100 Ohms and supports a maximum incremental frequency of 250 kHz.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The VT-HNC100-1-1X-130-3 digital axis controller is produced by Bosch Rexroth Indramat and forms part of the VT-HNC Digital Axis Controllers series. Within the Digital NC control HNC100 product series, this unit serves as the closed-loop control core for hydraulic positioning tasks, delivering command, feedback, and sequencing for servovalves, transducers, and pump drives on a single machine axis. The axis version is configured for one hydraulic axis, which keeps valve and sensor control on a dedicated channel for predictable motion behavior in presses, die-cushion systems, and molding equipment.

Analog command quality is supported by an output resolution of 1.25 mV, enabling fine valve current modulation. For current feedback channels, the module presents a precision shunt of 100 Ω ±0.2%, paired with 5 µA resolution so differential-pressure sensors or load cells on a 4–20 mA loop are sampled accurately. Voltage feedback lines see 200 kΩ ±2% impedance and 5 mV resolution, while high-impedance sensor inputs exceed 10 MΩ to avoid loading delicate signal sources. Incremental encoder ports accept edge rates up to 250 kHz, and SSI links handle 28-bit absolute data for position acquisition. Program and nonvolatile data storage are secured in 1 MB of flash plus 8 KB of EEPROM, both identified as component series 1, and total board demand stays at 8 W for compact control cabinets. Digital inputs use 3 kΩ ±10% pull-ups.

Execution speed is supplied by a 16/32-bit MC68376 processor that accesses 256 KB of RAM for cyclic interpolation and error handling during closed-loop operation. Each transistorized output can deliver up to 50 mA, enabling direct drive of indicator lamps or pilot valves without external amplifiers. Serial commands and software downloads are routed through an RS-232 interface that operates at 9.6 KBaud, supporting parameter transfer and service communication.

Analog Output Resolution
1.25 mV
Axis Version
Version for 1 hydraulic axis
Component Series
1
Current Input Resistance
100 Ohm ±0.2%
Current Input Resolution
5 uA
Digital Input Resistance
3 kOhm ±10%
Digital Output Current
50 mA
Eeprom
8 KB
Flash Memory
1 MB
Impedance Input Resistance
>10 MOhm
Incremental Max Frequency
250 kHz
Power Consumption
8 W
Processor
16/32-bit MC68376
Product Series
Digital NC control HNC100
Ram
256 KB
Rs232 Baud Rate
9.6 KBaud
Ssi Data Width
28 bits
Voltage Input Resistance
200 kOhm ±2%
Voltage Input Resolution
5 mV
  • VT-HNC100-1-1X/130/3 R900958999
  • VTHNC10011X1303
  • vt-hnc100-1-1x-130-3
  • vt-hnc100-1-11-130-3
  • vt-hnc100-1-12-130-3
  • vt-hnc100-1-13-130-3
  • vt-hnc100-1-14-130-3
  • vt-hnc100-1-15-130-3
  • vt-hnc100-1-16-130-3
  • vt-hnc100-1-17-130-3
  • vt-hnc100-1-18-130-3
  • vt-hnc100-1-19-130-3

Frequently Asked Questions about VT-HNC100-1-1X-130-3:

Q: How many axes can the VT-HNC100-1-1X-130-3 control?

A: The VT-HNC100-1-1X-130-3 controller supports one hydraulic axis in this version.

Q: What is the analog output resolution of the VT-HNC100-1-1X-130-3?

A: Analog output steps can be adjusted as finely as 1.25 mV on this controller.

Q: What is the maximum digital output current for this controller?

A: The digital output channels on the VT-HNC100-1-1X-130-3 can provide up to 50 mA each.

Q: How much memory is available on the VT-HNC100-1-1X-130-3?

A: This model features a memory configuration with 256 KB RAM, 8 KB EEPROM, and 1 MB flash memory for programming and operation.

Q: What is the maximum incremental encoder frequency accepted by the VT-HNC100-1-1X-130-3?

A: The incremental encoder input supports frequencies up to 250 kHz for high-speed feedback.


Internal Product Review

  • ‘‘The VT-HNC100-1-1X-130-3 is a Bosch Rexroth Indramat digital axis controller configured for 1 hydraulic axis, with a 16/32-bit MC68376 processor for responsive control. Precise signal handling comes through 1.25 mV analog output resolution and 250 kHz incremental max frequency, making the unit a strong choice for demanding hydraulic motion applications.’’