4.95 based on 202 reviews

🙶 Great response and customer service. Back-order item was shipped sooner than expected as well. 🙷

VT-HNC100-1-1X-130-2 Bosch Rexroth Indramat

MPN: R900553128

No Tariffs On US Orders
  • Rated 4.3 (40 total ratings)
  • Straightforward Pricing: No Rush Fees, No Credit Card Fees
Ask for Availability

Preparing your secure checkout page...

The Bosch Rexroth Indramat VT-HNC100-1-1X-130-2 is a digital axis controller from the VT-HNC Digital Axis Controllers series designed for one hydraulic axis. It features 4 voltage inputs with 5 mV resolution, 4 current inputs with 5 µA resolution, and two current outputs. This controller includes a MC68376 processor, 256 KB RAM, 1 MB flash memory, and has a power consumption of 8 W.

Quote Request Form:

Warranty
Wake Industrial Warranty

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The VT-HNC100-1-1X-130-2 is a digital axis controller produced by Bosch Rexroth Indramat and supplied within the VT-HNC Digital Axis Controllers series. Designed as a control module for hydraulic positioning loops, the unit supervises a single servo-controlled hydraulic axis in industrial automation tasks such as presses or injection-molding equipment. By interpreting sensor feedback and issuing proportional valve commands, the controller performs closed-loop motion control that aligns hydraulic actuators with numerical set points generated by the supervising machine control.

Analog measurement channels are arranged as 4 current inputs with 100 Ω ±0.2% input resistance and a resolution of 5 µA, plus four voltage inputs with 200 kΩ ±2% input resistance and a minimum step size of 5 mV. The axis board operates with an incremental encoder interface rated to 250 kHz, allowing precise position feedback. Program execution relies on the MC68376 32-bit microcontroller, while application code and parameter sets are stored in 1 MB of flash memory. The RS-232 service port communicates at 9.6 kbaud for setup and diagnostics, which matches legacy tooling used on many hydraulic machines. The module supports control of 1 hydraulic axis, integrating loop closure within the unit.

Actuator commands leave the board through 2 current outputs that drive proportional valve coils and through 4 voltage outputs suited for ±10 V interfaces. Each voltage channel can source or sink up to ±10 mA, which covers most servo-valve demands. Nonvolatile configuration backups occupy 8 KB of EEPROM, and dynamic data such as position loops run from 256 KB of RAM. Total module draw remains at 8 W, so cabinet thermal loading is minor. The component is in series 1 of the HNC100 line, and its power demand fits typical 24 V DC control supplies used alongside pump controllers and pressure transducers.

Axis Version
Version for 1 hydraulic axis
Component Series
1
Current Input Resistance
100 Ω ±0.2 %
Current Input Resolution
5 µA
Current Inputs
4
Current Outputs
2
Eeprom
8 KB
Flash Memory
1 MB
Incremental Max Freq
250 kHz
Max Voltage Output Current
±10 mA
Power Consumption
8 W
Processor
MC68376
Product Series
Digital NC control HNC100
Ram
256 KB
Rs232 Speed
9.6 KBaud
Voltage Input Resistance
200 kΩ ±2 %
Voltage Input Resolution
5 mV
Voltage Inputs
4
Voltage Outputs
4
  • VT-HNC100-1-1X/130/2
  • VTHNC10011X1302
  • vt-hnc100-1-1x-130-2
  • vt-hnc100-1-11-130-2
  • vt-hnc100-1-12-130-2
  • vt-hnc100-1-13-130-2
  • vt-hnc100-1-14-130-2
  • vt-hnc100-1-15-130-2
  • vt-hnc100-1-16-130-2
  • vt-hnc100-1-17-130-2
  • vt-hnc100-1-18-130-2
  • vt-hnc100-1-19-130-2

Frequently Asked Questions about VT-HNC100-1-1X-130-2:

Q: What type of axis version does the VT-HNC100-1-1X-130-2 controller support?

A: The VT-HNC100-1-1X-130-2 axis controller is designed for a single hydraulic axis version.

Q: How many current and voltage inputs are available on the VT-HNC100-1-1X-130-2?

A: This model provides four current inputs and four voltage inputs for signal processing.

Q: What is the current input resistance of the VT-HNC100-1-1X-130-2 controller?

A: The current input resistance on this controller is rated at 100 Ω ±0.2%.

Q: What are the memory specifications of the VT-HNC100-1-1X-130-2 controller?

A: The VT-HNC100-1-1X-130-2 has a total of 1 MB flash memory and 256 KB RAM onboard.

Q: What is the maximum incremental frequency handled by the VT-HNC100-1-1X-130-2 controller?

A: This controller can process incremental signals at a maximum frequency of 250 kHz.


Internal Product Review

  • ‘‘The VT-HNC100-1-1X-130-2 is a digital axis controller for 1 hydraulic axis with efficient 8 W power consumption. Four voltage inputs and four voltage outputs support precise signal handling in hydraulic control applications. A 250 kHz incremental max frequency highlights strong responsiveness for demanding motion tasks.’’