4.95 based on 202 reviews

🙶 Wake was very helpful in getting us a servo motor and drive for our tube mill line. This was the first tim... 🙷

VT-HNC100-1-14-134 Bosch Rexroth Indramat

Available, Ships in 1-2 weeks

Preparing your secure checkout page...

The Bosch Rexroth Indramat VT-HNC100-1-14-134 is part of the VT-HNC Digital Axis Controllers series and is designed for use with a single hydraulic axis. It operates on 18 to 36 VDC with a power consumption of 8 watts and features current input and output ranges of 4 to 20 mA. The controller supports voltage input and output ranges of ±10 V and is equipped with a 16/32-bit MC68376 processor.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The VT-HNC100-1-14-134 digital axis controller is manufactured by Bosch Rexroth Indramat for closed-loop position and force control on hydraulic machinery. It belongs to the VT-HNC Digital Axis Controllers series, a subset of the HNC100 Digital NC Control family. This module coordinates valve and transducer signals so that a hydraulic axis follows NC motion commands generated by a PLC or CNC. By converting reference positions into proportional current or voltage outputs, the device handles feedback and drive tasks that would otherwise require a separate motion card in industrial automation.

Internally, the version supplied here is configured for 1 hydraulic axis, giving one complete control loop for position, velocity, and pressure. Analog command inputs accept 4 to 20 mA with a measured input resistance of 100 Ω ±0.2%, while differential voltage references up to ±10 V are also supported at an input impedance of 200 kΩ. Corresponding outputs can reproduce 4 to 20 mA or ±10 V so that proportional valves receive the proper drive signal. For high-resolution displacement transducers, the encoder interface captures feedback pulses up to 250 kHz, and program storage relies on 1 MB of Flash EPROM backed by 8 KB of EEPROM for parameter sets and 256 KB of RAM for dynamic data.

The control logic is executed by a 16/32-bit MC68376 microprocessor, and the card draws just 8 W from a supply of 18 to 36 VDC, minimizing cabinet heat. Operating temperature is rated for 0 to 50 °C, with safe storage between -20 and +70 °C, allowing installation in most machine halls. Serial diagnostics are handled through an RS-232 port fixed at 9.6 kbaud, and the controller is series 1.

Axis Version
Version for 1 hydraulic axis
Bus Connection
CANopen
Component Series
1
CPU Type
16/32 Bit MC68376
Current Input Range
4 to 20 mA
Current Input Resistance
100 Ω ±0.2%
Current Output Range
4 to 20 mA
Design
Heavy Duty
Digital Inputs/outputs
16
Eeprom
8 KB
Encoder Max Frequency
250 kHz
Flash Eprom
1 MB
Housing Type
Wall Mounting
Hydraulic Axes
1 Axis
Industry Use
Hydraulic Systems
Maximum Axes Control
4 Axes
Modular Design
Yes
Operating Temperature
0 to 50 °C
Operating Voltage
18 to 36 VDC
Operational Environment
Extreme Industrial Settings
Position Transducer
Incremental-SSI
Power Consumption
8 W
Processor
16/32-bit MC68376
Product Line
Bosch Rexroth Indramat
Product Series
Digital NC control HNC100
Ram
256 KB
Rs232 Baud Rate
9.6 KBaud
Storage Temperature
-20 to +70 °C
Voltage Input Range
±10 V
Voltage Input Resistance
200 kΩ ±2%
Voltage Output Range
±10 V
Voltage Range
18 to 36 VDC

Frequently Asked Questions about VT-HNC100-1-14-134:

Q: How many hydraulic axes can the VT-HNC100-1-14-134 controller operate?

A: The VT-HNC100-1-14-134 is designed to control a single hydraulic axis.

Q: What is the required operating voltage for the VT-HNC100-1-14-134?

A: The operating voltage for this controller ranges from 18 to 36 VDC.

Q: What are the current input and output ranges of the VT-HNC100-1-14-134?

A: This model supports input and output current ranges of 4 to 20 mA.

Q: What is the encoder maximum frequency for the VT-HNC100-1-14-134?

A: The maximum supported encoder frequency is 250 kHz.

Q: What is the recommended operating temperature range for this controller?

A: Operating temperatures for the VT-HNC100-1-14-134 are between 0 and 50°C.

  • vt-hnc100-1-14-134
  • VT-HNC1-1-14-134
  • VTHNC100114134
  • vthnc100114134
  • VT-HNCI00-1-14-134
  • VT-HNC1O0-1-14-134
  • VT-HNC10O-1-14-134
  • VT-HNC100-I-14-134
  • VT-HNC100-1-I4-134
  • VT-HNC100-1-14-I34
  • VT-HNCIOO-I-I4-I34
  • VT-HNC10-1-14-134
  • VTHNC100-1-14-134
  • VT-HNC1001-14-134
  • VTHNC1001-14-134
  • VT-HNC100-114-134
  • VTHNC100-114-134
  • VT-HNC100114-134
  • VTHNC100114-134
  • VT-HNC100-1-14134

Internal Product Review

  • ‘‘The VT-HNC100-1-14-134 is a digital axis controller configured for 1 hydraulic axis, offering a focused solution for electrohydraulic motion applications. Support for 18 to 36 VDC operation and 8 W power consumption makes the controller especially practical for efficient cabinet integration. A 250 kHz encoder max frequency and ±10 V voltage input range give the unit precise, responsive signal handling.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo
Vallen logo