VT-HNC100-1-11/134/5

Ask for Availability

Preparing your secure checkout page...

The VT-HNC100-1-11/134/5, part of Bosch Rexroth Indramat's VT-HNC Digital Axis Controllers, operates on a voltage range of 18 to 36 VDC. It features a standard RS232 serial interface at 9.6 KBaud and supports Profibus DP, CANopen, or INTERBUS-S. The unit measures approximately 71 x 155 x 204 mm.

Warranty
Wake Industrial Warranty

Quote Request Form:

To contact sales for pricing and lead time:

Payment Methods

Visa
Mastercard
AmEx
Wire Transfer

Shipping Methods

DHL
UPS
FedEx
Freight

Our Credentials

Cary Chamber
DUNS Registered
SAM Registered
BBB Accredited

Product Description:

The Bosch Rexroth Indramat VT-HNC100-1-11/134/5 controller belongs to the VT-HNC Digital Axis Controllers series and ensures precise motion control for industrial systems.

This product generates normalized signals between 4 mA and 20 mA with an additional capacity to deliver ±23 mA temporary power surge. This controller matches standard industrial equipment because its current output load resistance stands at 500 Ohms. The analog output shows 1.25 mV precision and stays under 15 mV error while running from -9.5 V to +9.5 V. It gently brings up to 35 mV deviations in both -10 V to -9.5 V and +9.5 V to +10 V ranges. The controller works with 18 to 36 VDC voltage which fits many types of industrial power systems. The VT-HNC100-1-11/134/5 offers 9.6 KBaud RS232 as a standard communications option plus supportive bus interfaces like Profibus DP up to 12 MBaud, CANopen, and INTERBUS-S to match different industrial network setups. Users can select between eight, sixteen, and twenty-four switching input and output channels.

All configurations offer low 2 volts or less and high outputs up to supply voltage with a maximum current rating of 50 mA. The incremental transducer input operates at high speed by processing signal levels between 0-1 V for logic low and 2.8-5.5 V for logic high. At 250 kHz of frequency, the transducer provides optimal feedback under fast situations. For analog input, the controller works with voltage levels from +10 V to -10 V at 5 mV resolution. It supports wider input voltages from +15 V to -15 V. The controller operates between 0 to 50 °C and stores from -20 to +70 °C as its mechanical dimensions measure 71 x 155 x 204 mm.

Analog Input Resolution
5 mV
Analog Input Voltage Range
±10 V (measurable; up to ±15 V)
Analog Output Non-linearity
15 mV within ±9.5 V; 35 mV for ±9.5 V to ±10 V
Analog Output Resolution
1.25 mV
Dimensions (W×H×D)
71×155×204 mm
Incremental Transducer Input Levels
0–1 V (low); 2.8–5.5 V (high)
Load Resistance (Current Outputs)
500 Ω
Max Non-normalized Output Current
±23 mA
Maximum Transducer Frequency
250 kHz
Normalized Output Current
4–20 mA
Operating Temperature Range
0 to 50 °C
Operating Voltage
18–36 V DC
Optional Bus Interfaces
Profibus DP (≤12 MBaud), CANopen, INTERBUS‑S
Serial Interface
RS232 at 9.6 kBaud
Storage Temperature Range
-20 to +70 °C
Switching Inputs
8, 16, or 24 channels
Switching Outputs
8, 16, 24 ch; low ≤2 V; high up to UO; Imax 50 mA

Frequently Asked Questions about VT-HNC100-1-11/134/5:

Q: What are the signal and power specifications of the VT-HNC100-1-11/134/5 controller?

A: The VT-HNC100-1-11/134/5 generates normalized signals between 4 mA and 20 mA, with the capability for ±23 mA during temporary surges, and operates on a current output load resistance of 500 Ohms. It functions with 18 to 36 VDC, accommodating a wide range of industrial power systems.

Q: What are the analog output characteristics and precision levels of the VT-HNC100-1-11/134/5 controller?

A: The VT-HNC100-1-11/134/5 offers analog output with 1.25 mV precision across a range of -9.5 V to +9.5 V, with error margins kept under 15 mV. Deviations up to 35 mV are noted in the extended ranges of -10 V to -9.5 V and +9.5 V to +10 V.

Q: What communication interfaces does the VT-HNC100-1-11/134/5 support?

A: The VT-HNC100-1-11/134/5 includes a standard 9.6 KBaud RS232 communication option, along with Profibus DP up to 12 MBaud, CANopen, and INTERBUS-S, facilitating versatile integration with different industrial network systems.

Q: What input/output and transducer capabilities does the VT-HNC100-1-11/134/5 controller have?

A: Users of the VT-HNC100-1-11/134/5 can choose between 8, 16, and 24 input and output channels with maximum currents of 50 mA. It also supports an incremental transducer input that handles high-frequency signals up to 250 kHz, ideal for fast feedback scenarios.

Q: What are the operational conditions and physical dimensions of the VT-HNC100-1-11/134/5?

A: The VT-HNC100-1-11/134/5 operates effectively between 0 to 50 °C and can be stored from -20 to +70 °C. Its compact dimensions are 71 x 155 x 204 mm, making it suitable for a variety of installation spaces within industrial environments.


Internal Product Review

  • ‘‘The VT-HNC100-1-11/134/5 controller, from the VT-HNC Digital Axis Controllers series, excels in delivering precise motion control for industrial systems. With advanced signal normalization and extensive communication options, this controller is ideal for integrating into various industrial network setups, ensuring reliable and accurate performance.’’

Motion Industries logo
3M logo
IBM logo
Gexpro Logo
Caterpillar logo
NASA logo
Ford logo